Installation

Installing the IntraSwitch

Installation Guidelines

Before installing the IntraSwitch 5212, carefully review the following guidelines.

Power Requirements

The source electrical outlet should be installed near the IntraSwitch 5212, be easily accessible, and be properly grounded.

Make sure the power source adheres to the following guidelines:

Voltage range: 100 to 240 VAC

Frequency range: 60/50 Hz

Maximum current: 1.6 A

Environmental Requirements

The IntraSwitch 5212 must be installed in a clean, dry, dust-free area with adequate air circulation to maintain the following environmental limits:

Temperature: 0° to 45° C

Relative Humidity: 5% to 85% non-condensing

Avoid direct sunlight, heat sources, or areas with high levels of electro-magnetic interference.

Cooling and Airflow

The IntraSwitch 5212 has two internal fans that cool the interior by drawing air through vents on the sides and forcing heated air out through holes in the rear.

Important! Do not restrict air flow by covering or obstructing air vents on the sides of the case.

Page 2-2

Page 24
Image 24
Asante Technologies 5212 Installing the IntraSwitch, Installation Guidelines, Power Requirements, Cooling and Airflow