Setting Up For Management

Out-of-Band Management

Out-of-band network management allows you to configure, manage, and monitor the IntraSwitch 5212 and each of its ports. You can perform these functions via the following method:

By attaching a terminal (or a terminal emulator) to the IntraSwitch 5212’s Console port and using the menu-driven Local Management Interface.

Out-of-band network management is guaranteed even when the in-band Ethernet network is down.

To access the IntraSwitch 5212’s Local Management Interface using out-of-band management:

1

Connect a stand-alone terminal or a PC running

 

a terminal emulator directly to the IntraSwitch

5212’s Console port using a straight-throughRS- 232 serial cable with a male connector.

Straight-Through

RS-232 Cable

 

 

 

 

 

 

 

 

 

 

 

 

 

IntraSwitch 5212

 

 

 

 

 

 

 

 

 

 

RS-232

100 Mbps

 

 

 

 

 

 

 

 

 

 

 

 

Pwr

 

 

 

 

 

 

 

 

 

 

 

Max Util

 

 

 

 

 

 

 

 

 

 

 

 

10/100

 

 

 

 

 

 

 

 

 

 

Console

FDP / COL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Link

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/100

1

2

3

4

5

6

7

8

9

10

11

12

MII

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

Console Port

(female; requires a male connector)

Figure 4-2 Connecting to the Console port

Stand-Alone Terminal or PC Running Terminal Emulation Software

2 Make sure both units are powered on.

If using a PC with a terminal emulator, make sure it is configured with the following terminal settings:

Bits Per Second: 9600

Data Bits: 8

Parity: None

Stop Bits: 1

Flow Control: None