GigaX Series L3 Managed Switch User Guide
85
password (old password, no password by default): <new password>
[Reboot]
User can reboot the switch by issuing the reboot command.
CLI command: sys reboot
[Upload]
No CLI command for this function. Refer to Boot ROM commands for this
function.
5.3.2 Physical Interface Commands
[Admin] [Enable/Disable]
Displays the port admin status, allow user to turn the port on or off.
CLI command : l2 port admin <port number> <enable/disable>
[Mode] [Auto/10M-Half/10M-Full/100M-Half/100M-Full/1G-Full]
Displays the current speed and duplex mode of the port. The speed and
duplex mode can be automatically detected when auto-negotiation is enabled
on a port.
CLI command : l2 port autoneg <port number> <enable/disable>
CLI command : l2 port speed <port number> <10/100/1000>
CLI command : l2 port duplex <port number> <full/half>
[Flow Control] [Enable/Disable]
Displays the IEEE802.3x flow control setting of a port. Note that this flow
control is operating only in full duplex mode.
CLI command : l2 port flow <port number> <enable/disable>
[Reload]
Restores the previous port settings from the configuration file.