Chapter 4. Administration
6.On the RADIUS server, set the access rights for each user according to the information in the table below:
Character | Meaning |
CGrants the user administrator privileges, allowing the user to configure the system.
WAllows the user to access the system via the Windows Client program.
J Allows the user to access the system via the Java Client program.
P Allows the user to access an attached Power Over the Net™ device.
L Allows the user to access log information via a Web browser.
PN | Restricts the user from accessing specified ports on the OSD port list. |
| Syntax: PN/1/2/3/4 (etc.) |
|
|
PV | Limits the user to only being able to view specified ports on the OSD |
| port list. |
| Syntax: PV/1/2/3/4 (etc.) |
|
|
UHK | Defines the OSD Hotkey (see page 85). |
| UHK0: Scroll Lock + Scroll Lock |
| UHK1: Ctrl + Ctrl |
|
|
UOL | Defines the OSD List Function (see The List Function, page 32). |
| UOL0: All |
| UOL1: Powered On |
| UOL2: Quick View |
| UOL3: Quick View + Powered On |
|
|
UODM | Selects how the Port ID displays (see page 85). |
| UODM0: Port Number + Port Name |
| UODM1: Port Number |
| UODM2: Port Name |
|
|
UODT | Determines the length of time in seconds that the Port ID displays on |
| the monitor after a port change (see ID Duration, page 85). |
| Syntax: UODTn (where n represents a number from |
|
|
UBUZ | Turns the beeper on or off (see page 85). |
| UBUZ0: Beeper Off |
| UBUZ1: Beeper On |
|
|
ULT | Sets the Logout Time. When there is no input from the user for the |
| amount of time set with this function, the user is automatically logged |
| out and will need to log in again. The valid Logout Timeout range is |
| from |
| Syntax: ULTn (where n represents a number from |
|
|
| (continues on next page) |
47