PROGRAMMING THE VSSI-PRO
PORT A : B
Again, there is probably no need for you to access this menu as it should be used for testing purposes only. You should rely on the setting chosen in ATM SELECT, but we will provide a brief overview of this menu. Press the “Up” or “Down” button to move the cursor to “PORT A : B” and press “Set”. The following
ASYNC
BISYNC
SDLC
EXIT
Figure 29: Port A : B Sub-Menu
ASYNC
Press the “Up” or “Down” button to move the cursor to “ASYNC” and press “Set”. The following
ADDRESS SETUP | ANY |
BAUD RATE | 2400 |
PARITY | NONE |
DATA BITS | 8 |
EXIT |
|
Figure 30: ASYNC Sub-Menu
ADDRESS SETUP
Choices: ANY, 1 through 254
Press the “Up” or “Down” button to move the cursor to “ADDRESS SETUP” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to toggle between values and press “Set” when the desired value is dis- played.
BAUD RATE
Choices: 1200, 2400, 4800, 9600, 14.4K, 19.2K, 28.8K, 38.4K, 57.6K, 115.2K
Press the “Up” or “Down” button to move the cursor to “BAUD RATE” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to cycle through the values and press “Set” when the desired value is displayed.
PARITY
Choices: NONE, EVEN, ODD
Press the “Up” or “Down” button to move the cursor to “PARITY” and press “Set”. The cursor will start flashing. Press the “Up” or “Down” button to toggle between values and press “Set” when the desired value is displayed.
26