RS-485NETWORKER | APPENDIX E |
| |
RS-485 NETWORKER
The RS-485 Networker is designed to convert the RS-232 serial port output of the VSSI-Pro to be a poll/select network. This allows all the transaction data to be collected by one computer for up to 64 VSSI-Pros.
APPLICATION
Many users of the VSSI-Pro want to capture all the transaction data from several units to one device. The RS-485 Networker allows all data from up to 64 VSSI-Pros to be recorded on one PC or sent to one DVR. The user can then later search data history for evaluation. With remote software like PC Anywhere, a remote location could dial into many sites and review exception history and provide a value added service their existing customers.
THEORY
The VSSI-Pro contains an internal data buffer of 24K bytes. The VSSI-Pro can also be programmed for this buffer to hold all the on-screen data or just exceptions optionally containing Time/Date and other trigger text. The “handshaking” option in the VSSI-Pro allows for external hardware handshaking for this output port to be controlled by the “RTS” input. When this hardware handshaking input is false, the data is saved to the internal buffer. When this input is true the data is sent out the serial port. The RS-485 Networker controls this handshaking signal to the VSSI-Pro and when the networker is addressed by the host the data from the VSSI-Pro is sent to the host. The data from each RS-485 Networker is saved to a log file on the PC which can be read later as a data history from each VSSI-Pro.
RS-485 NETWORK
Up to 64 RS-485 Networkers can be connected on one RS-485 two-wire network. A unique address for each networker is set by its internal dipswitch. The protocol is basically poll/select. The baud rate is set at 19.2K.
RS-232 to RS-485 CONVERTER
A standard PC or laptop is used with the supplied software. The RS-232 to RS-485 Converter converts the PC or DVR RS-232 to RS-485. The handshaking signals of the PC control the direction of the RS-485 communications.
| | | | RS-485 Networker 1 | |
| | Triport | | | | | | | |
| | | | RS-232 | |
| | | VSSI-Pro 1 | Cable | RS-485 |
| | | | | | | |
ATM 1 | | | | | | Cable |
| | | | | |
| | Triport | | RS-232 | |
| | Cable | | | |
| | | VSSI-Pro “n” | RS-485 Networker “n” | |
Hydra RS-232
Controller Cable
RS-485 to RS-232
Converter
COM 1 (DB-9) COM 2 (DB-25)
DVR
MODEM
ATM “n”
“n” means up to 64 Cash Registers / VSSI-Pros / RS-485 Networkers can be connected on one RS-485 Network
Figure 1E: Connection Diagram for RS-485 Network
VSSI-Pro VIDEO SERIAL ATM INTERFACE