PROGRAMMING THE VSSI-PRO

NOTE "

In any of these tests, you can pause the data scrolling by holding down either the “Up”or “Down” button.

The VSSI-Pro is now waiting for data from the ATM. Enter a transaction. If the VSSI-Pro is receiving data, it will appear in three separate lines, scrolling from right to left across the bottom of the on-screen display. The first line is the transaction information. The second and third lines represent the HEX equivalent of the data in the first line.

0 Data

3HEX MS nibble

0HEX LS nibble

If you perform this test and do not receive any data then check all connections to the VSSI-Pro.

TRANSMIT [ TX ] TEST

In the Transmit Test, the VSSI-Pro sends a predefined ASCII pattern to further test the hardwire connections of the system. Press the “Up” or “Down” button to move the cursor to "TRANSMIT [ TX ] TEST" and press "Set". The following display will appear (example only):

RX BAUDRATE : TX BAUDRATE :

PARITY :

DATA BIT :

HANDSHAKING :

TRANSMITTING :

19200

19200 NONE

8

OFF

Figure 47: TRANSMIT [ TX ] TEST Display

Press “Set” to return to the previous menu.

RX/TX TEST

In the RX/TX Test, the VSSI-Pro echoes whatever it receives to further test the hardwire connections of the system. Press the “Up” or “Down” button to move the cursor to "RX/TX TEST" and press "Set". The following display will appear (example only):

RX BAUDRATE : TX BAUDRATE :

PARITY :

DATA BIT :

HANDSHAKING : ECHOING :

19200

19200 NONE

8

OFF

Figure 48: RX/TX TEST Display

Press “Set” to return to the previous menu.