Appendix A: Parameter List

Parameter name

 

Value

 

Description

 

 

 

 

 

 

 

ServerPassword

 

= pass

 

The Supervisor, Administrator or Root user password used for

 

 

 

 

 

basically all protocols; i.e. HTTP, NetWare bindery, SMB user-level,

 

 

 

 

SNMP and FTP. Once written into the configuration file, the

 

 

 

 

password will not be shown but replaced with eight *’s,

 

 

 

 

representing the password.

Domain/GroupName

 

=

 

Name of theStorPoint CD workgroup in SMB. If not specified, the

 

 

 

 

StorPoint CD will appear in the workgroup that comes first in

 

 

 

 

alphabetical order.

SecurityMode

 

= shareLevel

 

Specifies the security mode used in SMB: userLevel or shareLevel.

NTDomainInstallation

 

= no

 

Set to yes when you want to install the StorPoint CD in an NT

 

 

 

 

domain.

EnableNBT

 

= yes

 

Enables SMB over NetBIOS/TCP/IP.

NBTscopeID

 

=

 

Defines the NetBIOS scope to which the StorPoint CD belongs.

EnableNetBEUI

 

= yes

 

Enables SMB over NetBIOS/NetBEUI.

NetBEUIFrameType

 

= auto

 

If set to auto, 802.2 or DIX will automatically be selected by

 

 

 

 

scanning the network. If required, the frame type can also be set to

 

 

 

 

either 802_2 or dix.

 

 

 

 

 

 

[NFS]

 

 

 

 

 

NFSEnable

 

= yes

 

Enables NFS.

DefaultUid

 

= -2

 

Default user id to be used when authenticating PCNFSD clients.

 

 

 

 

Disable by setting the parameter to 0 (zero).

PCNFSDAuthentServer

 

= 0.0.0.0

 

The IP address of the PCNFSD authentication server used for

 

 

 

 

authenitcating PCNFSD clients. The default 0.0.0.0 disables the

 

 

 

 

function.

ExportVolumes

 

= yes

 

Enables export of each new disc inserted as a mount point. If you

 

 

 

 

restore the factory default settings, all the currently inserted discs

 

 

 

 

will be exported.

LowerNonCase

 

= yes

 

Set to yes to displays non-case sensitive file systems in lower case.

 

 

 

 

 

 

[SNMP]

 

 

 

 

 

GetCommunityName

 

= public

 

Specifies the community that has read only access to all supported

 

 

 

 

SNMP objects except writeCommunity, SupervisorPassword and

 

 

 

 

ftpPassword. It corresponds to the readCommunity SNMP object.

TrapDestination

 

= 0.0.0.0

 

Specifies the IP address which SNMP traps are sent to. It

 

 

 

 

corresponds to the trapAddress SNMP object. Default is 0.0.0.0,

 

 

 

 

i.e. all SNMP traps are disabled.

TrapCommunityName

 

= public

 

Specifies the community for all generated SNMP traps. It

 

 

 

 

corresponds to the trapCommunity SNMP object.

SystemContact

 

=

 

Optional entry which should be in plain text and may be used to

 

 

 

 

show the name of the system contact person.

SystemName

 

=

 

Optional entry which should be in plain text and may be used to

 

 

 

 

show the name of the location of the system.

SystemLocation

 

=

 

Optional entry which should be in plain text and may be used to

 

 

 

 

show the name of the location of the system.

AuthenticationTrap

 

= disabled

 

Disables the SNMP authentication failure traps. It corresponds to

 

 

 

 

the snmpenableAuthenTraps (MIB-II) SNMP object.

 

 

 

 

 

 

[NetWare]

 

 

 

 

 

NWEnable

 

= yes

 

Enables NetWare support.

IPXEnable

 

= yes

 

Enables the IPX protocol.

Frame_802_2

 

= auto

 

Enables the 802.2 frame type.

Frame_802_3

 

= auto

 

Enables the 802.3 frame type (Ethernet versions only).

Frame_EthernetII

 

= auto

 

Enables the Ethernet II frame type (Ethernet versions only).

Frame_SNAP

 

= auto

 

Enables the SNAP frame type.

NetWareIP_Enable

 

= no

 

Enables NCP over IPX/UDP (NetWare/IP).

NetWareIP_DSS_Server

 

=

 

The IP address of the DSS server.

PureIPEnable

 

= yes

 

Enables NCP over TCP/IP (PureIP).

ServerName

 

= AXIS<nnnnnn>_NW

 

NetWare server name to be presented to the NetWare clients.

 

 

 

 

Default is AXIS<nnnnnn>_NW where nnnnnn are the last six digits

 

 

 

 

of the serial number.

InternalNetAddress

 

= nn-nn-nn-nn

 

Internal network address. Default is nn-nn-nn-nnwhere nnnnnnnn

 

 

 

 

are the last eight digits of the serial number.

BurstMode

 

= on

 

Enables burst mode.

ShowAllVolumes

 

= yes

 

Shows all drives and discs also at SYS level.

 

 

 

 

 

 

AXIS StorPoint CD E100 User’s Manual

119

Page 119
Image 119
Axis Communications user manual Axis StorPoint CD E100 User’s Manual 119

CD E100 specifications

The Axis Communications CD E100 is a cutting-edge network video door station designed to enhance security and accessibility for residential and commercial properties. This innovative device combines video surveillance and intercom functionality, making it an essential component of modern security systems.

One of the standout features of the CD E100 is its high-definition video quality. The device is equipped with a 2 megapixel sensor that delivers crisp and clear video footage, ensuring that users can easily identify visitors at their doorstep. The wide-angle lens provides a 180-degree field of view, reducing blind spots and allowing for better overall surveillance coverage.

The CD E100 is also designed to withstand various environmental conditions, boasting an IP66 rating for weather resistance. This means it can operate effectively in rain, snow, and extreme temperatures, making it a reliable choice for outdoor installations. Additionally, the door station's robust materials protect it from vandalism and tampering, ensuring durability and longevity.

One of the key technologies integrated into the CD E100 is Power over Ethernet (PoE). This allows the device to receive power and data through a single network cable, simplifying installation and reducing clutter. PoE capability ensures that users can easily install the device in locations where standard power outlets may not be available.

The CD E100 also features two-way audio functionality, which allows users to communicate with visitors in real-time. This feature is particularly beneficial for enhanced security, as it enables property owners to speak to individuals at their door without needing to open it. The integrated microphone and speaker provide clear audio quality, ensuring effective communication.

Smart technology is also a highlight of the CD E100, supporting remote access via mobile devices. Users can monitor their entry points in real-time through the Axis Companion app or any compatible video management software. This feature not only enhances security but also provides convenience for users, as they can respond to visitors even when they are not home.

Overall, the Axis Communications CD E100 is a versatile and reliable video door station that combines advanced technology with user-friendly features. Its high-quality video, robust construction, and smart capabilities make it an excellent choice for those looking to enhance their security systems while maintaining ease of use.