Section 2: Installing the StorPoint CD

Date & Time 1. On the Server Settings page, click the Server icon and then Change... to open the Server Settings dialog box.

2.Open the Date & Time page.

3.Specify the time zone in which the StorPoint CD operates. Refer to “Time Zone Parameter Values ” on page 122.

4.To set the time using a time synchronization source, choose Automatically and specify the time source:

Network

 

 

environment

Time Source:

You must also specify the ...

 

 

 

NetWare IPX

Novell Directory

Time Source parameter on the Network

 

Services (NDS)

Settings NetWare page:

 

 

- SAP or

 

 

- List of server names.

 

 

 

NetWare PureIP

Novell Directory

Time Source parameter on the Network

NetWare/IP

Services (NDS)

Settings NetWare page:

 

 

- List of server names or IP addresses.

 

 

 

TCP/IP

Network Time

NTP Server parameter on the Server

 

Protocol (NTP) *

Settings Date & Time page:

 

 

- Name or IP address of the time server.

Windows NT

Microsoft Windows

 

domains

NT Network (SMB)

 

 

 

 

* Note: NTP is not natively supported by Windows NT servers. You will need third party software.

To set the time manually, choose Manually and specify the date in yyyy-mm-ddformat, and time in hh:mm:ss format using the 24 hour clock.