Axis Communications CD E100 user manual 120

Models: CD E100

1 163
Download 163 pages 31.49 Kb
Page 120
Image 120

Appendix A: Parameter List

Parameter name

Value

Description

BinderyEnable

= yes

Enables bindery mode login. When using NDS, set to no to increase

 

 

system security. The Supervisor can always login in bindery mode

 

 

even if this parameter is set to no.

BindAuthentication

=

Name or IP address of the server used for authenitcating clients.

NDSEnable

= yes

Enables NDS mode.

NDSTreeName

=

Name of the tree where you wish to install the StorPoint CD.

NDSServerContext

=

Distinguished name of the context in the NDS tree where you wish

 

 

to install the StorPoint CD, e.g. Corp.Acme.

NDSAdminName

=

Distinguished name of a user or administrator with Supervisor or

 

 

Create rights to the context where you want to install the

 

 

StorPoint CD, e.g. Admin.Acme.

NDSAdminPassword

=

Password for the administrator defined in NDSAdminName. Once

 

 

written into the configuration file, the password will not be shown

 

 

but replaced with *’s, representing each letter of the password.

NDSInstall

= no

Set to install when you are ready to install the StorPoint CD in

 

 

NDS, or forced to overwrite the NDS server object.

NDSRightsStorage

= NDS

Set to NDS to store the access rights in the NDS tree. Set to File to

 

 

store the access rights in a file on the Novell server. This is

 

 

necessary if you do not allow schema extensions in your NDS tree,

 

 

or if you do not have Supervisor access rights. Set to Local to store

 

 

access rights locally in the StorPoint.

NDSRightsFile

=

If you have set NDSRightsStorage to File, specify the whole path to

 

 

the file on the Novell file server using this syntax:

 

 

SERVER/VOLUME:DIR/.../FILE.DAT where SERVER is a NetWare

 

 

server name or IP address. The specified directory must exist and

 

 

the StorPoint CD must have Read, Write, Create, Erase, Modify

 

 

and File Scan rights. The StorPoint CD will create the file once you

 

 

start adding trustees.

TimeSyncSources

= SAP

If IPX is enabled, use SAP or a list of time servers containing NDS

 

 

server names. If PureIP is enabled, use a list of time servers

 

 

containing IP addresses, DNS names or NDS server names.

 

 

 

[AFP]

 

 

AFPEnable

= yes

Enables AFP.

AppleTalk_Enable

= yes

Enables AFP over AppleTalk.

AFPIP_Enable

= yes

Enables AFP over TCP/IP.

ServerName

=

The server name in the AFP environment. Default is AXIS<nnnnnn>

 

 

where nnnnnn are the last six digits of the serial number.

ZoneName

=

The zone name to which the StorPoint CD server belongs.

AuthenticationServer

=

Name of the server used for authenitcating clients.

AuthenticationEnable

= no

Enables the authentication server. Default is no.

 

 

 

[SMTP]

 

 

Primary Mail Server

= mail

Name or IP address of the primary mail server.

Secondary Mail Server

=

Name or IP address of the secondary mail server.

Administrator Address

=

The administrator’s e-mail address.

Mail Log Events

= no

No means that no log events will be sent via e-mail to the

 

 

administrator. Error means that only errors will be sent to the

 

 

administrator. Warning means that only warnings will be sent to the

 

 

administrator. All means that all logged events will be sent via e-mail

 

 

to the administrator

 

 

 

[HDCache]*

 

 

CacheMode*

= mirror

The default caching method to be used each time you insert a new

 

 

disc in one of the drives. None means no caching. Partial means that

 

 

the directory structure is cached to allow fast file browsing. Mirror

 

 

means complete caching. The hard disk will contain a complete

 

 

copy of the mirrored disc.

ClearAllDisks*

= no

Set to yes to remove all information from the hard disk.

EnableMaxAutoArchiveSize*

= no

Set to yes to enable the Max Auto Archive Size option.

MaxAutoArchiveSize*

= 650

Specifies the maximum disc size to auto archive.

AutoEject*

= no

Set to yes to enable the Auto Eject function.

EnableLowDiskWarning*

= yes

Set to no to disable the Low Disk Warning option.

LowDiskTreshold*

= 650

Specifies for which disc size a low disk warning shall be displayed.

 

 

 

120

AXIS StorPoint CD E100 User’s Manual

Page 120
Image 120
Axis Communications CD E100 user manual 120

CD E100 specifications

The Axis Communications CD E100 is a cutting-edge network video door station designed to enhance security and accessibility for residential and commercial properties. This innovative device combines video surveillance and intercom functionality, making it an essential component of modern security systems.

One of the standout features of the CD E100 is its high-definition video quality. The device is equipped with a 2 megapixel sensor that delivers crisp and clear video footage, ensuring that users can easily identify visitors at their doorstep. The wide-angle lens provides a 180-degree field of view, reducing blind spots and allowing for better overall surveillance coverage.

The CD E100 is also designed to withstand various environmental conditions, boasting an IP66 rating for weather resistance. This means it can operate effectively in rain, snow, and extreme temperatures, making it a reliable choice for outdoor installations. Additionally, the door station's robust materials protect it from vandalism and tampering, ensuring durability and longevity.

One of the key technologies integrated into the CD E100 is Power over Ethernet (PoE). This allows the device to receive power and data through a single network cable, simplifying installation and reducing clutter. PoE capability ensures that users can easily install the device in locations where standard power outlets may not be available.

The CD E100 also features two-way audio functionality, which allows users to communicate with visitors in real-time. This feature is particularly beneficial for enhanced security, as it enables property owners to speak to individuals at their door without needing to open it. The integrated microphone and speaker provide clear audio quality, ensuring effective communication.

Smart technology is also a highlight of the CD E100, supporting remote access via mobile devices. Users can monitor their entry points in real-time through the Axis Companion app or any compatible video management software. This feature not only enhances security but also provides convenience for users, as they can respond to visitors even when they are not home.

Overall, the Axis Communications CD E100 is a versatile and reliable video door station that combines advanced technology with user-friendly features. Its high-quality video, robust construction, and smart capabilities make it an excellent choice for those looking to enhance their security systems while maintaining ease of use.