30 en Hardware setupDivar 700 Series
4.8 | RS232 COM port connections |
| |||
|
| The RS232 COM ports are used to connect a PC to the unit for service purposes. Use a null- | |||
|
| modem cable to connect the serial port of the PC to the unit. The Baud rate can be selected in | |||
|
| the menu system. |
|
|
|
|
| Specifications |
|
|
|
|
| Connector type: |
| ||
|
| Maximum input voltage: ±25V |
| ||
|
| Communicaton protocol: Output signals according | |||
|
| COM 1 | COM 2 |
| |
|
| Figure 4.12 RS232 COM port connectors |
| ||
|
|
|
|
|
|
|
| Signal name |
| Pin number | Description |
|
|
|
|
|
|
|
| DCD_in |
| 1 | Carrier detection signal (not used) |
|
|
|
|
|
|
|
| RX |
| 2 | RS232 receive signal |
|
|
|
|
|
|
|
| TX |
| 3 | RS232 transmit signal |
|
|
|
|
|
|
|
| N/C |
| 4 | No connection |
|
|
|
|
|
|
|
| System ground |
| 5 | System ground |
|
|
|
|
|
|
|
| N/C |
| 6 | No connection |
|
|
|
|
|
|
|
| RTS |
| 7 | RS232 request to send signal |
|
|
|
|
|
|
|
| CTS |
| 8 | RS232 clear to send signal |
|
|
|
|
|
|
|
| N/C |
| 9 | No connection |
|
|
|
|
|
|
Table 4.1 RS232 console port socket
F.01U.246.471 v3.6 2011.11 | Installation and Operation manual | Bosch Security Systems |