Bosch Appliances 700 RS232 COM port connections, Signal name, Pin number, Description

Models: 700

1 120
Download 120 pages 48.02 Kb
Page 30
Image 30
RS232 COM port connections

30 en Hardware setupDivar 700 Series

4.8

RS232 COM port connections

 

 

 

The RS232 COM ports are used to connect a PC to the unit for service purposes. Use a null-

 

 

modem cable to connect the serial port of the PC to the unit. The Baud rate can be selected in

 

 

the menu system.

 

 

 

 

 

Specifications

 

 

 

 

 

Connector type: 9-pole D-type male connector

 

 

 

Maximum input voltage: ±25V

 

 

 

Communicaton protocol: Output signals according EIA/TIA-232-F

 

 

COM 1

COM 2

 

 

 

Figure 4.12 RS232 COM port connectors

 

 

 

 

 

 

 

 

 

Signal name

 

Pin number

Description

 

 

 

 

 

 

 

 

DCD_in

 

1

Carrier detection signal (not used)

 

 

 

 

 

 

 

 

RX

 

2

RS232 receive signal

 

 

 

 

 

 

 

 

TX

 

3

RS232 transmit signal

 

 

 

 

 

 

 

 

N/C

 

4

No connection

 

 

 

 

 

 

 

 

System ground

 

5

System ground

 

 

 

 

 

 

 

 

N/C

 

6

No connection

 

 

 

 

 

 

 

 

RTS

 

7

RS232 request to send signal

 

 

 

 

 

 

 

 

CTS

 

8

RS232 clear to send signal

 

 

 

 

 

 

 

 

N/C

 

9

No connection

 

 

 

 

 

 

Table 4.1 RS232 console port socket