Divar 700 SeriesHardware setup en 35
4.13USB connectors
Four USB connectors are located at the rear panel of the unit. For convenience, one USB port is located on the front of the unit to connect a mouse or memory device.
USB USB
Figure 4.17 USB ports
4.14 | External alarm I/O connection | ||
|
| Alarm inputs and outputs are supplied via a | |
|
| output connection board supplied with the unit simplifies all alarm connections to the unit. | |
|
| Connecting the inputs | |
|
| Each (alarm) input line can be switched by a contact from devices such as pressure pads, | |
|
| passive | |
|
| N/C. Configure the alarm inputs as N/O or N/C in the menu system. The default is N/O. Inputs | |
|
| ||
|
| Specifications |
|
|
| Alarm input impedence: Internal | |
|
| Input voltage range: | |
|
| Input voltage treshold: low voltage 0.8 V maximum, high voltage 2.4 V minimum | |
|
| Cable cross section: AWG | |
|
| Connecting the alarm outputs | |
|
| The four alarm output relays respond to input alarms and triggers. Configure the alarm | |
|
| outputs as N/O or N/C in the menu system. The relays are active for the duration of the driving | |
|
| event. Only connect resistive loads to the alarm output relays. Do not exceed 30 Vac, 40 Vdc, | |
|
| 500 mA (continuous), or 10 VA on an alarm output relay's contacts. | |
|
|
|
|
|
| Output number | Function |
|
|
|
|
|
| 1 | Alarm |
|
|
|
|
|
| 2 | Video loss |
|
|
|
|
|
| 3 | Controllable with control center |
|
|
|
|
|
| 4 | Controllable with control center |
|
|
|
|
Table 4.7 External alarm I/O
DANGER!
Electrical voltage. Risk of electric shock and damage to the unit.
The contacts must not be used at AC line voltages.
Specifications
Switching current (resistive): 500 mA maximum
Carrying power: 10 VA maximum
Switching voltage (resistive): 30 VAC / 40 VDC maximum
Cable cross section: AWG
Bosch Security Systems | Installation and Operation manual | F.01U.246.471 v3.6 2011.11 |