Divar 700 SeriesAdvanced configuration en 67
| recordings, the clock resumes advancing at the normal pace and normal recording behaviour |
| is resumed. |
| If you want the recorder to set back the clock more than 10 minutes, but also want the unit to |
| resume recording immediately, you should either delete all recordings manualy, or set the |
| recorder time ahead of the latest recording time. |
6.1.3 | Time Server |
Figure 6.3 Configuration menu - International - Time Server
–The Use time server function synchronizes the time of the unit with the time of a network time server or another Divar unit. Fill in the IP address of the network time server. If a time server is not present on the same subnet, the unit searches for a suitable time server outside its own network. Make sure the Divar gateway is set correctly to find the time server. Ensure that firewalls do not block NTP traffic via port 123.
–Click Synchronize to start time synchronization.
Automatic time synchronization (done once every four hours) can only change the clock by a maximum of 10 minutes (see Note under Section 6.1.2 Time/date).
Bosch Security Systems | Installation and Operation manual | F.01U.246.471 v3.6 2011.11 |