Bosch Appliances VJR SERIES installation manual Preparing the Wiring, Power

Models: VJR SERIES

1 194
Download 194 pages 27.01 Kb
Page 77
Image 77

AutoDome Junior HD

Preparing the Wiring en 77

 

 

8Preparing the Wiring

All AutoDome Junior HD units provide three standard cables: an Ethernet cable, a 24 VAC power input cable for the camera, and an alarm input/output cable. An Outdoor AutoDome Junior HD unit provides an additional 24 VAC power input cable for the heater.

The Ethernet connection carries control and video information and can deliver power to the camera via the Power-over- Ethernet Plus (PoE+) standard. Refer to Section 9 Audio, Alarms and Relay Connections, page 82, for alarm connection information.

CAUTION!

Installation should only be performed by qualified service personnel in accordance with the National Electrical Code or applicable local codes.

CAUTION!

All wires for installation applications must be routed through a grounded conduit.

8.1Power

The recommended power cable is a 2-conductor, 14-18 gage cable, depending on the distance.

 

Watts

14 AWG

16 AWG

18 AWG

 

 

(2.5 mm)

(1.5 mm)

(1.0 mm)

 

 

 

 

 

Camera, All models

 

 

 

 

24 VAC to AutoDome Junior HD

17

670 ft

421 ft

265 ft

 

 

(204 m)

(128 m)

(81 m)

Heater, Outdoor models only

 

 

 

 

24 VAC to Heater

25

455 ft

287 ft

180 ft

 

 

(139 m)

(67 m)

(55 m)

 

 

 

 

 

Table 8.1 Max. Wire Distance from Power Supply to AutoDome Junior HD

Bosch Security Systems, Inc.

Installation Manual

F.01U.275.803 6.0 2012.11