CARE AND MAINTENANCE

gUse the cleaning brush or a vacuum cleaner to remove any lint and dust from the race and bobbin thread sensor and the surrounding area.

aCleaning brush

bRace

cBobbin thread sensor

Note

Do not apply oil to the bobbin case.

If lint or dust collects on the bobbin thread sensor, the sensor may not operate cor- rectly.

hInsert the bobbin case so that the projection on the bobbin case aligns with the spring.

aProjection

bSpring

CAUTION

Be sure that the bobbin case is correctly installed. Otherwise, the needle may break.

iInsert the tabs on the needle plate cover into the needle plate, and then slide the cover back on.

Note

Never use a bobbin case that is scratched; otherwise, the upper thread may become tangled, the needle may break, or sewing performance may suffer. For a new bobbin case (part code: XC3153-251 (green marking on the screw), XC8167-451 (no color on the screw)), contact your nearest authorized service center.

If the needle plate has been removed it is especially important to reinstall the needle plate and tighten the screws prior to installing the bobbin case.

Cleaning the Cutter in the Bobbin Case Area

The cutter below the needle plate should be cleaned. If dust or lint accumulate on the cutter, it will be difficult to cut the thread when the “Thread Cutter” button is pressed or the automatic thread cutting function is used. Clean the cutter when the thread is not easily cut.

aFollow steps a through e in “Cleaning the Race” to remove the needle plate cover.

bUse the screwdriver included with the machine to unscrew and remove the needle plate.