21
5. Match and connect equ ipment wires to proper terminals of each connector
block.
6. Push any excesswire into wall and againstEquipment Control Module.
Sealh ole in wall to prevent air leaks. Leaks can affectoperatio n and cause
incorrect temperature and/or humidity measurement.
7. Remove 2--wire pigtail from thermostat mounting base and attach to
EquipmentControl Module terminalblock (terminalsV+ and Vg). Attach
two--wirepigtailto the back of the Display Module via 2 pin, keyed con-
nector.
8. ReattachDisplay Module body to Equipment Control Moduleby first
setting on at top and then push bottom corners to snap intop lace. See Fig.
15.
A07221
Fig.15 -- Reattach DisplayModule