OF (off) — The Humidifier Pad Reminder is d isabled and will never be
displayed.
1--24— The number of months after whichthe Humidifier Pad Reminder icon
willbe displayed, “CHECK HUM PAD”.
Default is OF (off).
Option30 — Programmable Fan (programmablemodels only)
This selection allows the homeowner to program the fan selection to “Auto ”or
“On” fan operation for each of the program schedule periods. Th isselectio n is
onlyavailable on programmablemodels.
OF (off)— Programmable fan is disabledand the homeowner must manually
select“Auto” or “On” forfan operation.
On — Programmablefan is enabled. The homeowner can program “Auto” or
“On” fan operation along with the heat and cool setpoints for each prog rammed
period. Whenthe program schedule is running, theprogrammed heat setpoint,
cool setpoint,and fan selection for that periodwill be used. If the homeowner
“overrides” the programmed fan setting by pressing th e fan button, the override
selection will remain in effectu ntil the next programmed period time.
Default is OF (off).
Option31 — Daylight Savings Time Configuration(programmable models
only)
This selection allows the installer to set the thermostat to automatically change
byone hour on the specified day,month, and week specified.
OF(off) — Daylight Savings TimeFunction disabled.
1,2 On — The first time the UP/DOWN button is pressed, the value of this
selectionchanges fromOF (off) to 1. When 1is displayed, the daysof the week
and clock digits will be turned on. The in stallerwill set th e startdate (S pring) for