22
9. Turn on powerto equipment. On power up, all display segmentswill
lightfor 5 sec. For the next 5 sec a 2--digitcode appears on largedisplay
whichidentifies AC/HP Controlconfiguration. Referto Option 33.
a. AC — 1--stageair conditioner, AC,HP
b. HP 1--stageheat pump, HP only
c. H — heating only system, AC, HP
d. C coolingonly system,AC, HP
Set AC/HP ControlConfiguration
Configuration options enablethe installer to configure the thermostat for a
particularinstallation. Most arenot presentedto the homeowner and therefore
must be properlyset by the installer. (Only those markedwith an asterisk *
below are availableto the homeowner.) The homeowner configurations are
described in theowner’s manual. A special procedureallows entry into the
configurationmode. While in configuration mode, upto 29 selections can be
made. Description of each selection and how to use the configuration mo de
follows.
CONFIGURATIONOPTIONS --SUMMARY
Option01 Equipment Type
Option 02 Clean Filter Timer Adjustment
Option 03* — Fahrenheit/Centigrade Selection
Option 04 Fan (G) on with W/W1 Selection
Option05 Room Air TemperatureSensing (programmable
modelsonly)
Option06 Cooling Lockout Below 55_F Selection (only
availableif outdoor airsensor is present)