Daylight Savings Time by setting the day of the week by selecting the
appropriatetriangleicon next to the days of the week, the month of the yearwill
beset in the clock hours location(range 1--12)and the week of the month will be
setin the clock minutes location.The week of the month selections willbe F, 2,
3,4, and L for First, 2nd, 3rd, 4th, and Last.So forthe first Sunday in April, the
display would show SUN, 4, F.When 2 is displayed, the installerwill then
choosethe end date for daylight savingstime (Fall). Toactivate the function, the
installerchanges the “2” by pressing the up button and “On” is displayed.The
setting shall be left “On” to enable the Daylig ht Savings Time function.
Default is OF (off).
Option32 — Furnace Heat Staging Control (availableonly when the HP
thermostat is configured to operate AC equipment).
1 — Thermostatcontrols W1 output only and furnacecontrols the turn on and
turnoffofhigherstagesofheat.
2— Thermostat will control theW1 and O/W2/B outputs.
Defaultis 1.
Option33 — Single or Two--PieceInstallation
This configurationallows the thermostatto compensate for the amount of heat
generated by the thermostat electronics to allo w more accurate sensing of the
temperaturesensor. The amountof heatcompensation will be differentbetween
single installation and two--piece installation.
Range:1P or 2P
1P — The installation is single piece.
2P — The installation is two separate pieces.
Defaultis 2P.