25
ACmodel — Range: AC, H, C.
HP operatesa single--speedheatpump with a fan coil.
AC — operates a single--speedAC.
H — operates a heat--onlysystem. Furnaceor fan coil only;
nooutdoor unit.
C operatesa cool only--system.OutdoorAC unit with an
indoorfan coil with no stripheaters.
Defaults
HP model defaults to HP.
AC model defaults to AC.
Option02 — Clean FilterTimer
Select hours of blower operation(heating, cooling, or fan) before CHECK
FILTERicon is displayed.With OF selected, icon will nevercome on, disabling
thisfeature. Timeselection can rangefrom 800 to 7200 hr by selectingnumbers
1through 9. (Time is 800 X numberselected.) Defaultis 4 (3200 hr).
Recommended selections are disposable filter --800to 2400 hr, media filter--2400
to 3200 hr,or electronic air cleaner--1600 to 2400 hr of blower operation.For
higher efficiency filter, please consult filter’s Installation Instruction for details.
Option03 — Fahrenheit/Centigrade
Selectbetween Fahrenheit (F) and Centigrade(C) operation. Factory default is
Fahrenheit(F).
Option04 — Fan (G) On WithW/W1
Thisselection determines whetherfan (G) output is to be On or OFF whenany
W/W1 (furnace or strip heat) output is On. Most furnaces and fan coils manage
theirown blowersand do not requireseparate G signal. For these applications,