3-33
CHAPTER 3. REPAIR INSTRUCTION
Power
Source
Stand
Color Viewer
Personal
Computer
CAMERA
BODY
ND-2
Filter
3.5.3 Imaging Process Adjustment
Tools Used
Personal Computer Color Viewer (5600° K)
Adjustment Software W-10 Filter (2 pcs.)
Compact Power Adapter CA-PS500 C-12 Filter
AC Cable FL-W Filter
DC Coupler DR-500 ND-2 Filter
INTERFACE CABLE IFC-200PCU
1 Click the Imaging Process button.
3 1. Attach the ND-2 Filters between the Lens and
the Color Viewer.
2. Place the camera so that the lens is set against
the center part of the Color Viewer.
3. Click the ADJUST button.
2 When the message on the right appears, go to 3.