Table 9 Ð Keypad Directory (cont)

Table 9 Ð Keypad Directory (cont)

SERVICE (cont)

SUBFUNCTION

KEYPAD ENTRY

 

 

DISPLAY

COMMENT

 

 

 

 

 

 

3 FACTORY

 

 

 

XXXXXXXX

Con®guration Code 5

CONFIGURATION (cont)

 

 

 

 

 

 

 

 

 

 

 

 

XXXXXXXX

Con®guration Code 6

 

 

 

 

XXXXXXXX

Con®guration Code 7

 

 

 

 

 

 

4 FIELD

 

 

 

FLD CFG

Adjustable Field Con®guration

CONFIGURATION

 

 

 

 

 

 

 

 

 

 

 

 

ENO X

CCN Element Address

 

 

 

 

BUS X

CCN Bus Number

 

 

 

 

BAUD X

CCN Baud Rate

 

 

 

 

FLUID X

Cooler Fluid Select (water/medium brine)

 

 

 

 

UNITS X

Display Unit Select (English/Metric)

 

 

 

 

DELAY X

Delay at Power Up (minutes)

 

 

 

 

NULA X

No. Circuit A Unloaders

 

 

 

 

NULB X

No. Circuit B Unloaders

 

 

 

 

HGB X

Hot Gas Bypass Select (used, not used)

 

 

 

 

SEQT X

Loading Sequence Select (equal circuit, staged circuit)

 

 

 

 

LEADT X

Lead/Lag Sequence Type

 

 

 

 

OPS X

Oil Pressure Switch Select (enable/disable)

 

 

 

 

HEADT X

Head Pressure Control Type

 

 

 

 

(none, air cooled, water cooled)

 

 

 

 

 

 

 

 

 

MM X

Motormaster Select

 

 

 

 

CSPTYP X

Cooling Set Point Control Select

 

 

 

 

CRTYP X

Cooling Reset Control Select

 

 

 

 

ERTYP X

External Reset Sensor Select

 

 

 

 

OATSEL X

Outdoor-Air Sensor Select

 

 

 

 

LSTYP X

Demand Limit Control Select

 

 

 

 

RAMP X

Ramp Load Select (enable, disable)

 

 

 

 

LOCK X

Cooler Pump Interlock Select

 

 

 

 

CPC X

Cooler Pump Control Select

 

 

 

 

REMA X

Remote Alarm Option Select (yes/no)

 

 

 

 

ALRST X

Allow Local/Stop/CCN Reset of Alarms (yes/no)

 

 

 

 

 

 

To toggle between inputs (Yes/No) Press:

(no) or

(yes)

 

 

 

 

 

 

 

5 SERVICE

 

 

 

SRV CFG

Service Con®gurations

CONFIGURATION

 

 

 

 

 

 

 

 

 

 

 

 

XXXXXXXX

Con®guration Code 8

 

 

 

 

XXXXXXXX

Con®guration Code 9

 

 

 

 

REFRIG X

Refrigerant

 

 

 

 

TDTYP X

Pressure Transducer Select

 

 

 

 

OPS X

Oil Transducer Set Point (psig)

 

 

 

 

LPS X

Low Pressure Set Point (psig)

 

 

 

 

FANTYP X

Fan Staging Select

 

 

 

 

SH X

EXV Superheat Set Point (F)

 

 

 

 

MOP X

EXV MOP Set Point (F)

 

 

 

 

ZM X

Z Multiplier

 

 

 

 

 

 

LEGEND

CCN Ð Carrier Comfort Network

EXV Ð Electronic Expansion Valve

MOP Ð Maximum Operating Pressure

*Will read ALARM or ALERT as appropriate.

²Must be con®gured.

**If applicable.

²²Not manually resettable.

NOTE: If metric option is selected under Manual background , temperature expressed as Celsius and pressure will be expressed as kPa.