LEGEND

C

Ð Contactor

CB

Ð Circuit Breaker

COM, COMM

Ð

Communications Bus

CPCS

Ð

Compressor Protection

 

 

Control Module

CR

Ð Compressor Contactor Relay

DGT

Ð Discharge Gas Thermostat (Optional)

DSIO

Ð Relay Module (Low Voltage)

HPS

Ð

High-Pressure Switch

LV

Ð

Low Voltage

NC

Ð Normally Closed

NO

Ð Normally Open

PL

Ð

Plug

PWR

Ð Power

SNB

Ð

Snubber

TB

Ð

Terminal Block

TRAN

Ð

Transformer

U

Ð Unloader

Fig. 11A Ð 24-V Safety Circuit Wiring (040-070)

Code 21 Reset thermistor failure (applies only to installa- tions having external temperature reset) (alert)

If temperature measured by this thermistor is outside range of ±40 to 240 F (±40 to 116 C), reset function is disabled and unit controls to normal set point. If temperature returns to the acceptable range, reset function is automatically en- abled. The cause of this fault is usually a bad thermistor, wiring error, or loose connection.

Code 22 Compressor A1 discharge pressure transducer failure (alert)

Code 23 Compressor B1 discharge pressure transducer failure (alert)

Code 24 Compressor A1 suction pressure transducer failure (alert)

Code 25 Compressor B1 suction pressure transducer failure (alert)

Code 27 Compressor B1 oil pressure transducer failure (alert)

If output voltage of any of these transducers is greater than 5 v, affected circuit shuts down without going through pum- pout process (Alerts 24-27). Other circuit continues to run. Reset is automatic if output voltage returns to the acceptable range, and circuit start-up follows normal sequence. The cause of this fault is usually a bad transducer or a wiring error.

Code 28 Low transducer supply voltage (alarm)

If transducer supply voltage is less than 4.5 v or greater than 5.5 v, unit shuts down without going through pumpout process. Reset is automatic if supply voltage returns to the acceptable range, and circuit start-up follows normal se- quence. The cause of this fault is usually a faulty trans- former or primary voltage is out of range.

Code 26 Compressor A1 oil pressure transducer failure (alert)

51

Page 51
Image 51
Carrier 30GN040-420 operating instructions COM, Comm, Dgt, Dsio, Hps, Pwr, Snb, Tran

30GN040-420 specifications

The Carrier 30GN040-420 is a well-regarded model within the industry of chillers, designed to deliver efficient cooling solutions for a variety of commercial applications. Its compact design and advanced technology make it an ideal choice for businesses looking to optimize their HVAC systems.

One of the standout features of the Carrier 30GN series is its flexibility. This chiller model is available in a range of capacities, specifically from 40 to 420 tons, allowing for customized solutions based on specific cooling demands. Such versatility enables this unit to cater to a broad array of installations, from small commercial spaces to larger industrial facilities.

The Carrier 30GN040-420 utilizes a scroll compressor design, known for its reliability and efficiency. The scroll technology allows for a reduction in the number of moving parts, resulting in lower maintenance costs and increased durability. Additionally, the unit operates with environmentally friendly refrigerants such as R-410A, promoting sustainability without compromising performance.

Energy efficiency is another significant aspect of this model. The 30GN series is designed to provide high energy efficiency ratios (EER), which translates to lower operational costs for users over the lifespan of the unit. This is particularly beneficial in an era where energy costs are consistently rising.

The advanced controls found within the Carrier 30GN040-420 further enhance its performance and ease of use. The unit is equipped with a microprocessor-based control system that allows for precise temperature management while providing valuable diagnostic information. This feature not only improves the overall reliability of the system but also facilitates proactive maintenance, reducing the risk of unscheduled downtime.

Moreover, the design of the Carrier 30GN040-420 emphasizes quiet operation, making it suitable for environments where noise levels must be minimized. This characteristic is critical for applications in hospitals, schools, or office buildings, where a peaceful atmosphere is essential.

In summary, the Carrier 30GN040-420 chiller provides a robust solution for businesses requiring dependable and efficient cooling. Its features, including flexible capacity options, reliable scroll compressors, energy-efficient performance, advanced controls, and quiet operation, position it as a top choice for various commercial and industrial applications. As technology continues to evolve, models such as the 30GN series remain at the forefront, meeting the demands of modern HVAC needs while ensuring sustainability and efficiency.