Troubleshooting
Install
38AUZ*16 Charging Chart Rtpf
Field Control Wiring
Dimension
Maintenance
Field Refrigerant Access Ports
Adjust Refrigerant Charge
Checklist
Safety
Page 52
Image 52
38AU
TOP BRACKETS
52
FRONT
BOTTOM
BRACKET
LEFT
BACK
RIGHT
C10367
Fig. 48 - Wind Baffle Installation — 15 Ton Units
Page 51
Page 53
Page 52
Image 52
Page 51
Page 53
Contents
Installation, Start---Up Service Instructions
Contents
Installation Guideline
Safety Considerations
Replacement/Retrofit R-22 to PuronR
Installation
Unit Damage Hazard
Mchx
Unit
Rtpf
38AUZ*25
38AUD*25
Unit Size 38AU
Refrigerant TYPE‡
Compressor
Condenser Fans
Pressurestat Settings kPa High Cutout
Nominal Capacity kW
Rtpf Shipping Charge kg
Scroll
Oil Charge A/B oz
Rtpf Shipping Charge A/B lb
Face Area sq ft total Rows/Fins per inch FPI
Operating Weight kg Novation Coil Al Tube
Rtpf Shipping Charge A/B kg
Oil Charge A/B L
Qty...r/s Motor Hp Nema Diameter mm
U Z a 2 5 a 0 G 6 a 0 a 0 a
Installation
Matching 38AU Model To Evaporator Coil
Jobsite Survey
Do not Bury Refrigeration Lines
Provide Safety Relief
Slab Mount
Equivalent Lengths for Common Fittings ft
Check 38AU Model with Evaporator Coil Connections
Suction Riser
Liquid Lift
38AUZ 16-25 Piping Recommendations Single-Circuit Unit
38AUD 16-25 Piping Recommendations Two-Circuit Unit
Vertical Separation outdoor unit above indoor unit
Insulate Suction Lines
Hot Gas Bypass
Install Filter Driers and Moisture Indicators
Refrigerant Specialties Part Numbers
Install Liquid Line Solenoid Valve
Capacity Control Liquid Line Solenoid Valve
Selecting an Accumulator
Make Piping Connections
Evacuation/Dehydration
Preliminary Charge
Field Power Supply
Units with Factory-Installed Disconnect
Fire Hazard
All Units
Convenience Outlets
Electrical Operation Hazard
Field Control Wiring
Convenience Outlet Utilization Notice Label
Control Transformer Wiring
Thermostat
Unit Wire/Fuse or Hacr Breaker Sizing Data
Unbalanced 3-Phase Supply Voltage
PRE-START-UP
START-UP
System Check
Preliminary Checks
Advanced Scroll Temperature Protection Astp
Adjust Refrigerant Charge
Using plotted operating point
Start Unit
38AUZ*25 Check Compressor Oil Level
Final Checks
38AUD*16 Charging Chart Novation
38AUZ*16 Charging Chart Rtpf
38AUD*16 Charging Chart Rtpf
38AUD*25 Charging Chart Rtpf
Typical 38AUZ Wiring Diagram 15 Ton 230V Tandem Unit Shown
Typical 38AUD Wiring Diagram 15 Ton 230V Dual Unit Shown
Operating Sequence
Base Unit Controls
Routine System Maintenance
Service
Refrigeration System
Equipment Damage Hazard
Factory High-Flow Access Ports
Field Refrigerant Access Ports
Liquid Line Filter Drier
Comfort Alert Diagnostic Module
Input Terminal Voltage
LED Status Codes
Lockout
Compressor Protection
38AUD Size 16 Cabinet
LPS
38AUZ,D Size 25 Cabinet
38AUZ*25 Compressor Assembly Rear View
Novation Coil Cleaning and Maintenance
Repairing Novation Condenser Tube Leaks
Coil Type Identification
NOVATIONt Type
Replacing NOVATIONt Condenser Coil
Routine Cleaning of Round-Tube Plate Fin Rtpf Coils
Unit Reliability Hazard
Troubleshooting
Problem Solution Compressor does not RUN
Compressor Stops on HIGH-PRESSURE Switch
Fastener Torque Values
Problem Solution Compressor Cycles on LOW-PRESSURE Switch
Compressor Running but Cooling Insufficient
Unit Operates TOO Long or Continuously
System is Noisy
Appendix a
Wiring Diagram List
Appendix B
Low Ambient Option Factory Installed
Troubleshooting
Appendix C
Operation
Motormaster Sensor Location
38AUZ*16 & 38AUD*16 Novation 38AUZ*16/25 & 38AUD*16/25 Rtpf
Dimensions --- Inches Unit Baffle
Wind Baffle Dimension
Dimensions --- MM Unit Baffle
Wind Baffles Fabrication
15 Ton Wind Baffle Brackets Fabrication
Front
Front Back Left Right
Catalog No 38AU---09SI
START-UP Checklist
II. PRE-START-UP Outdoor Unit
Check Voltage Imbalance
Top
Page
Image
Contents