3-6

Using Advanced Setup

3.To change the sampling interval setting, move the highlighting to “Interval”. Next, press 1 to display a dialog box for specifying the sampling interval.

• The range of values you can select depends on the current sampling mode setting.

If this sampling mode is selected:

This is the allowable setting range:

 

 

Realtime

0.2 to 299 sec

 

 

Fast

20 to 500 μsec

 

 

Extended

5 to 240 min

 

 

Period

“=Trigger” only (no value input required)

 

 

Sound

20 to 27 μsec

 

 

Clock

“=Trigger” only (no value input required)

 

 

Normal

0.0005 to 299 sec

4.To change the number of samples setting, move the highlighting to “Number”. Next, press 1 to display a dialog box for specifying the number of samples.

You can specify a value in the range of 10 to 30,000.

The total sampling time shown at the bottom of the dialog box is calculated by multiply- ing the “Sampling Interval” value you specified in step 3 by the number of samples you specify here.

Important!

When all of the following conditions exist, a “Distance” setting appears in place of the “Number” setting. See “To configure the Distance setting” (page 3-7) for information about configuring the “Distance” setting.

Channel Setup (page 3-3): 2(VRNR) - [Photogate] - [Pulley]

Sampling Mode (page 3-5): Clock

5.To change the warm-up time setting, move the highlighting to “Warm-up”. Next, perform one of the function key operations described below.

Note

The “Warm-up” setting will not be displayed on the Sample Setup screen if “Fast”, “Sound” or “Extended” is currently selected as the sampling mode.

To do this:

Press this key:

 

 

 

Have the warm-up time for each sensor set automatically

1

(Auto)

 

 

 

Input a warm-up time, in seconds, manually

2

(Man)

 

 

 

Disable the warm-up time

3

(None)

 

 

 

Important!

When the following condition exists, an “FFT Graph” setting appears in place of the “Warm-up” setting. See “To configure the FFT Graph setting” (page 3-7) for information about configuring the “FFT Graph” setting.

Sampling Mode (page 3-5): Fast