TN3270 Server Commands 45
show extended channel tn3270-server pu
show extended channel tn3270-server pu
Use theshow extended channel tn3270-server pu privileged EXEC command to display the PU
configuration parameters, statistics and all the LUs currently attached to the PU.
show extended channelslot/2 tn3270-server pu pu-name
Syntax Description
Command Mode
Privileged EXEC
Usage Guideline
The display shown depends on whether the PU is a direct PU or a SNA session switch PU.
Sample Displays
Thefollowing is sample output on the Cisco 7000 from the show extended channel tn3270-server
pucommand for a direct PU:
router# show extended channel 3/2 tn3270-server pu EXT2
name(index) ip:tcp xid state link destination r-lsap
EXT2(1) 172.28.1.106:23 05D18092 ACTIVE tok 0 4000.7470.00e7 08 04
idle-time 0 keepalive 0 unbind-act discon generic-pool perm
bytes 100 in, out; frames 90 in, 4 out; NegRsp 6 in, 0 out
actlus 4, dactlus 0, binds 0
lu name client-ip:tcp state model frames in out idle for
1 EXT2001 171.69.176.34:1897 ACTIVE 327805 1 1 4:32:49
2 EXT2002 never connected ACTIVE 1 1 4:32:49
Thefollowing is sample output on the Cisco 7000 from the show extended channel tn3270-server
pucommand for a SNA session switch PU:
router# show extended channel 3/2 tn3270-server pu INT1
name(index) ip:tcp xid state link destination r-lsap
INT1(5) 172.28.1.106:23 05D18091 ACTIVE dlur MPX.GOAN1
idle-time 0 keepalive 0 unbind-act discon generic-pool perm
bytes 50 in, out; frames 87 in, 2 out; NegRsp 3 in, 0 out
actlus 2, dactlus 0, binds 0
lu name client-ip:tcp state model frames in out idle for
1 GOAN1X01 never connected ACTIVE 1 1 0:32:14
2 GOAN1X02 never connected ACTIVE 1 1 0:32:14
extended channel
slot/2 (Optional) Specifies a particular CIP in the router where slot is the
slot number. The port value for a TN3270 server will always be 2.
pu-name PU name that uniquely identifies this PU.