Caution The ports labeled Ethernet, 10BASE-T, Token Ring, Console, and AUX are safety
extra-low voltage (SELV) circuits. SELV circuits should only be connected to
other SELV circuits.
Note RP cables are not available from Cisco, but are available from any commercial
cable vendor.
Note To comply with Telcordia GR-1089 NEBS standard for electromagnetic
compatibility and safety, connect all console, auxiliary, Ethernet, and
BITS (PRP2) interfaces only to intrabuilding or nonexposed wiring or cabling.
The intrabuilding cable must be shielded and the shield must be grounded at both
ends.
PRP Console Port Signals
The console port on the PRP is a DCE RJ-45 receptacle. Tabl e 3-3 lists the
signal-to-pin correspondence for the PRP console port.
Table3-3 PRP Console Port Signals
Console Port Pin Signal Input/Output Description
11
1. These pins are not connected.
—— —
2 DTR Output Data Terminal Ready
3 TxD Output Transmit Data
4 GND Signal Ground
5 GND Signal Ground
6 RxD Input Receive Data
7 DSR Input Data Set Ready