Cisco Systems ASA5555IPSK9, ASA5515K9, kygjygcjgf manual Installing the DC Input Power, 4-15, PS0PS1

Models: ASA5515K9

1 80
Download 80 pages 31.89 Kb
Page 69
Image 69
PS0PS1

Chapter 4 Maintenance and Upgrade Procedures for the ASA 5500-X

Removing and Installing the Power Supply

Step 4 Connect the power cable. If you are installing two power supplies for a redundant configuration, plug each one into a power source (we recommend a UPS).

Step 5 Power on the appliance if you powered it off to replace the only power supply.

Step 6 Check the PS0 and PS1 indicators on the front panel to make sure they are green. On the back panel of the appliance, make sure the power supply indicator on the bottom of each installed power supply is green. (See Figure 4-19.)

Figure 4-19 Back Power Supply Indicators

PS0PS1

331087

Installing the DC Input Power

Warning The covers are an integral part of the safety design of the product. Do not operate the unit without the covers installed. Statement 1077

Warning When you install the unit, the ground connection must always be made first and disconnected last. Statement 1046

Warning Before performing any of the following procedures, ensure that power is removed from the DC circuit. Statement 1003

Warning Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030

Cisco ASA 5500-X Series Hardware Installation Guide

4-15

Page 69
Image 69