CDE Detail Description

PRI AOC – S Charge Information (Tag: 4223)

Table 1-167 PRI AOC – S Charge Information Description Form

Name: PRI AOC – S Charge Information

Tag: 4223

Source: MDL

Description/Purpose: Contains Charging Tariff Information that has been setup for AOC – S Supplementary services. It comprises the following data items:

tariff id and timestamped (from octet 1–6) may be repeated (up to 11 occurrences). The repetition depends on the number of different tariffs applied for a given call and the maximum number of tariffs allowed per day is 11.

Format: BE

Data Value:

Length in Octets: 6, 12, 18, 24, 30, 36, 42, 48, 54, 60, or 66

Octets 1-2: integer value range 0-9999 (tariff id)

Octets 3-6: Time in UNIX format (timestamp associated with tariff id in octets 1-2)

Extended Data Value: No extended value.

General Information: Octets 1-6 may be repeated up to 11 times to allow for up to 11 tariff changes during the call. Timestamps in octets 3-6 is in Unix format (as CDB Timepoint tag 4001).

MGC Release: Release 9.5(2) and later.

PRI AOC – D Charge Information (Tag: 4224)

Table 1-168 PRI AOC – D Charge Information Description Form

Name: PRI AOC – D Charge Information

Tag: 4224

Source: MDL

Description/Purpose: Contains Charging Tariff Information that has been setup for AOC – D Supplementary services. It comprises the following data items:

tariff id and timestamped (from octet 5–10) may be repeated (up to 11 occurrences). The repetition depends on the number of different tariffs applied for a given call and the maximum number of tariffs allowed per day is 11.

Format: BE

Data Value:

Length in Octets: 10, 16, 22, 28, 34, 40, 46, 52, 58, 64, or 70

Octets 1-4 : Total Charge (integer value)

Octets 5-6: integer value range 0-9999 (tariff id)

Octets 7-10: Time in UNIX format (timestamp associated with tariff id in octets 5-6)

Extended Data Value: No extended value.

General Information: Octets 1-6 may be repeated up to 11 times to allow for up to 11 tariff changes during the call. Timestamps in octets 3-6 is in Unix format (as CDB Timepoint tag 4001).

MGC Release: Release 9.5(2) and later.

 