Chapter 1 Billing Interfaces

CDE Detail Description

Originating Member (Tag: 4009)

Table 1-72 Originating Member Description Form

Name: Originating Member

Tag: 4009

Source: MDL

Description/Purpose: Contains the originating trunk member number within the originating trunk group. There can be 214 originating members when the MGC is configured for ANSI, and 212 originating members when configured for ITU.

Format: BE

Length in Octets: 2

Data Value: There can be 214 members for ANSI, and 212 for ITU, and is represented as an integer.

Extended Data Value: No extended value.

General Information:

MGC Release: Release 5.0 and later.

Calling Number (Tag: 4010)

Table 1-73 Calling Number Description Form

Name: Calling Number

Tag: 4010

Source: MDL

Description/Purpose: These are the numbers of the calling number.

Format: IA5

Length in Octets: 1 to 96

Data Value: Holds the digits of the calling number.

Extended Data Value: No extended value.

General Information: In the SS7/C7 environment, the calling number (Tag 4010) holds only the digits of the calling number; it does not include any NOA, or other information. NOA and other information are presented by their own CDE(s).

MGC Release: Release 5.0 and later.

Charged Number (Tag: 4011)

Table 1-74 Charged Number Description Form

Name: Charged Number

Tag: 4011

Source: MDL

Description/Purpose: If the protocol contains a parameter called charged number the contents are deposited into this CDE in order to define unique number of the party to be billed. In this case, it may or may not be the calling number. However, if the charged number parameter does not exist, the calling number is placed by default into this CDE as a default billed party.

Format: IA5

Length in Octets: 1 to 96

Data Value: The digits of the number being billed.

Extended Data Value: No extended value.

General Information:

MGC Release: Release 5.0 and later.

 

 

Cisco Media Gateway Controller Software Release 9 Billing Interface Guide

 

 

 

 

 

 

OL-1089-11

 

 

1-101

 

 

 

 

 