Chapter 1 Billing Interfaces

CDE Detail Description

User Service Information (Tag: 2001/ANSI)

Table 1-24

User Service Information Description Form

 

 

 

 

Name: User Service Information

Tag: 2001

Source: MDL

 

 

 

 

Description/Purpose: This parameter is used to send the data transmission parameters to the distant exchange. The field format is the same as the format for the bearer capability information element from ANSI standard T1.607.

Format: ANSI T1.113

Length in Octets: 2 to 13

 

 

Data Value: For more detail, please refer to ANSI T1.113.

Extension: octet continues through the next octet, 1 last octet

Coding standard: the setting should be 00 for CCITT standard, 10 for national

Information Transfer Capability. For POTS calling, this field is set at one of the following:

00000 Speech

01000 Unrestricted digital information

01001 Restricted digital information

10000 3.1 kHz audio

10001 Unrestricted digital information with tone and announcements Transfer Mode (octet 2)

00 Circuit mode

10 Packet mode

7.3Information Transfer Rate 00000 Packet mode only 10000 64 kb

00011 384 kb

10100 1472 kb

10101 1536 kb

10111 1920 kb

11000 Multi-rate

Structure, Configuration, Establishment, and so on: please refer to T1.113

Extended Data Value: No extended value.

General Information:

Cisco Media Gateway Controller Software Release 9 Billing Interface Guide

1-50

OL-1089-11

 

 

Page 72
Image 72