Chapter 1 Billing Interfaces

CDE Detail Description

Table 1-177 Rejecting Location Label Direction Form (continued)

Extended Data Value: No extended value.

General Information: For calls with location labels defined, a call admission check must be made once the terminating side is set up. This involves reading internal tables to get call limit data and active call counter data. If the call limit threshold is reached, then the call is rejected against that location label. This record provides an indication of whether or not this call rejection was assigned to the MGC originating (inbound) or MGC terminating (outbound) side.

This tag is added to the CDB only if the call admission check results in rejection.

MGC Release: Release 9.6(1) and later.

Total Circuit Count (Tag: 4234)

Table 1-178

Total Circuit Count Description Form

 

 

 

 

Name: Total Circuit Count

Tag: 4234

Source: Engine

 

 

 

Description/Purpose: Identifies the total circuits (CICs) defined for a trunk group or signaling service.

 

 

 

 

Format: BE

 

Length in Octets: 4

 

 

 

 

 

Data Value:

0 or greater (unsigned)

ANSI/ITU Variations: None.

Extended Data Value: No extended value.

General Information:

MGC Release: Release 9.4(1) patch and later.

Total Circuits Unavailable Count (Tag: 4235)

Table 1-179 Total Circuits Unavailable Count Description Form

Name: Total Circuits Unavailable Count

Tag: 4235

Source: Engine

Description/Purpose: Identifies the total circuits (CICs) currently unavailable within a trunk group or SigPath. The definition of unavailable is a circuit that is either “blocked” or “OOS”. A circuit that is already blocked, but which then goes OOS, is not reported additionally as unavailable, since it was already unavailable.

Format: BE

Length in Octets: 4

 

 

Data Value:

0 or greater

ANSI/ITU Variations: None.

Extended Data Value: No extended value.

General Information:

MGC Release: Release 9.4(1) patch and later.

H323 Destination (Tag 4236)

Table 1-180 H323 Destination Description Form

 

 

Cisco Media Gateway Controller Software Release 9 Billing Interface Guide

 

 

 

 

 

 

OL-1089-11

 

 

1-151

 

 

 

 

 

Page 173
Image 173
Cisco Systems OL-1089-11 manual Total Circuit Count Tag, Total Circuits Unavailable Count Tag, H323 Destination Tag