Power Levels

Power Levels

The devices in an EnergyWise network are from different manufacturers. To manage power usage consistently, EnergyWise uses a set of power levels.

If a domain member sends an end point a request to change the power level, the end point determines the appropriate action.

Table 1-1

Power Levels

 

 

 

 

 

Category

 

Level

Description

 

 

 

 

Operational

 

10

Full

 

 

 

 

 

 

9

High

 

 

 

 

 

 

8

Reduced

 

 

 

 

Standby

 

7

Medium

 

 

 

 

 

 

6

Frugal

 

 

 

 

 

 

5

Low

 

 

 

 

 

 

4

Ready

 

 

 

 

 

 

3

Standby

 

 

 

 

Nonoperational

 

2

Sleep

 

 

 

 

 

 

1

Hibernate

 

 

 

 

 

 

0

Shut off

 

 

 

 

The range is from 0 to 10.

The default is 10.

A Cisco switch does not support level 0. You cannot turn off the power on a switch.

A PoE end point, such as IP phone, receives power from a PoE switch port.

The power level is for the port.

The port supports levels 0 to 10.

If the port power level is 0, the port is powered off.

If the power level is from 1 to 10, the port is on.

Cisco EnergyWise Configuration Guide

 

OL-19806-03

1-5

 

 

 