Cisco Systems OL-19806-03 manual Energywise query, Collect delta usage, Timeout timeout

Models: OL-19806-03

1 84
Download 84 pages 59.14 Kb
Page 59
Image 59

Chapter 3 EnergyWise CLI Commands

energywise query

energywise query

To display power information and to set the power level of domain members, use the energywise query command in privileged EXEC mode.

energywise query importance importance {keywords word,word,... name name} collect {delta usage} [timeout timeout]

energywise query importance importance {keywords word,word,... name name} set level level [timeout timeout]

energywise query importance importance {keywords word,word,... name name} sum {delta usage} [timeout timeout]

Syntax Description

importance importance

Only entities with importance values less than or equal to the specified value

 

 

respond to the query.

 

 

The importance range is from 1 to 100.

 

 

 

 

keywords word,word,...

Filters the results based on one or more keywords.

 

 

When specifying multiple keywords, separate the keywords with commas,

 

 

and do not use spaces between keywords.

 

 

You can enter alphanumeric characters and symbols such as #, (, $, !, and

 

 

&.

 

 

Do not enter an asterisk (*) or a blank space between the characters or

 

 

symbols.

 

 

 

 

name name

Filters the results based on the name.

 

 

For the wildcard, use * or name* with the asterisk at the end of the name

 

 

phrase.

 

 

You can enter alphanumeric characters and symbols such as #, (, $, !, and

 

 

&.

 

 

Do not enter an asterisk (*) or a blank space between the characters or

 

 

symbols.

 

 

 

 

collect {delta usage}

Displays power-usage information in watts (W) from the domain members

 

 

and end points.

 

 

delta—Display the delta vector with the difference between the actual

 

 

power usage and the maximum power usage for each power level for

 

 

what-if calculations.

 

 

usage—Display the actual power usage.

 

 

 

 

timeout timeout

(Optional) Sets the time in seconds that the management station waits for

 

 

query results.

 

 

The range is from 1 to 180.

 

 

 

 

 

Cisco EnergyWise Configuration Guide

 

 

 

 

 

 

OL-19806-03

 

 

3-15

 

 

 

 

 

Page 59
Image 59
Cisco Systems OL-19806-03 manual Energywise query, Collect delta usage, Timeout timeout