Chapter 1 Managing Single Entities

Configuring Recurring Events

 

Command

Purpose

Step 7

 

 

energywise level level recurrence importance

(Optional) Schedules a power-on or power-off event.

 

importance {at minute hour day_of_month

level level —Specifies the power level

 

month day_of_week time-range

 

To power off the end point, enter 0.

 

time-range-name}

 

 

To power on the end point

 

 

If it is a PoE end point, enter 10.

 

 

If it is another powered device, enter a power level from

 

 

1 to 10. The end point determines the appropriate action.

 

 

importance importance—The event occurs if the importance

 

 

value of the end point is less than or equal to the importance

 

 

value. The range is from 1 to 100.

 

 

at minute hour day_of_month month

 

 

day_of_week—Specifies the time (24-hour format) in cron

 

 

format for the recurring event.

 

 

minute—The range is from 0 to 59. Use * for the

 

 

wildcard.

 

 

hour—The range is from 0 to 23. Use * for the wildcard.

 

 

day_of_month—The range is from 1 to 31. Use * for the

 

 

wildcard.

 

 

month—The range is from 1 (January) to 12 (December).

 

 

Use * for the wildcard.

 

 

day_of_week—The range is from 0 (Sunday) to 7

 

 

(Sunday). Use * for the wildcard.

 

 

time-rangetime-range-name—Specifies the time range for

 

 

the recurring event.

 

 

The event uses the switch time.

 

 

Repeat this step to schedule another event.

Step 8

 

 

end

Returns to privileged EXEC mode.

Step 9

 

 

show energywise recurrence

Verifies your entries.

Step 10

 

 

copy running-config startup-config

(Optional) Saves your entries in the configuration file.

 

 

 

 

Cisco EnergyWise Configuration Guide

1-24

OL-19806-03

Page 32
Image 32
Cisco Systems OL-19806-03 manual Energywise level level recurrence importance, Show energywise recurrence