3-16
Cisco EnergyWise Configuration Guide
OL-19806-03
Chapter 3 EnergyWise CLI Commands
energywise query
Command Default The timeout value is 6 seconds.
Command Modes Privileged EXEC
Command History
Usage Guidelines In the results from the sum keyword, the Responded total is not accurate. The Queried total is accurate
and is the number of entities that respond to the query.
Caution Use this query with care. It affects the entity on which you enter the command and other
domain devices that match the query criteria.
Examples These examples show how to filter with the entity name.
Switch# energywise query importance 50 name phone* collect usage
EnergyWise query, timeout is 3 seconds:
Host Name Usage Level Imp
---- ---- ----- ----- ---
2.2.2.21 phone 0.0 (W) 10 1
2.2.2.21 phone 15.4 (W) 10 1
2.2.2.21 phoneA 0.0 (W) 10 1
2.2.2.22 phone 0.0 (W) 10 1
2.2.2.21 phoneB 0.0 (W) 10 1
2.2.2.22 phoneC 15.4 (W) 10 1
set level level Sets the power level of the domain entities, including the PoE ports.
The range is from 0 to 10.
sum {delta | usage}Displays the summary of the power-usage information from domain
members and end points.
delta—Display the delta vector.
usage—Display the actual power usage.
Release Modification
12.2(50)SE This command was introduced on the Catalyst 3750-E, 3750, 3560-E, 3560, and
2960 switches.
12.2(52)SE The timeout timeout keywords were added on the Catalyst 3750-E, 3750, 3560-E,
3560, and 2960 switches.
12.2(52)SG This command was introduced on Catalyst 4500 switches.
12.2(54)SG The timeout timeout keywords were added on Catalyst 4500 switches.
12.2(55)SE The default timeout value was changed from 3 seconds to 6 seconds.
12.2(33)SXI4 This command was introduced on the Catalyst 6500 switches. See the Cisco IOS
Release Notes for Cisco EnergyWise, EnergyWise Phase 2 for the specific devices.
15.0(1)M2 This command was introduced on Cisco Integrated Service Routers Generation 2
(ISR G2), including Cisco 3900, 2900, and 1900 ISRs.