Cisco Systems OL-19806-03 manual Keywords word,word, Recurrence, Importance importance, Time-range

Models: OL-19806-03

1 84
Download 84 pages 59.14 Kb
Page 53
Image 53

Chapter 3 EnergyWise CLI Commands

energywise (interface configuration)

keywords word,word

(Optional) Assigns at least one keyword for the port.

 

When assigning multiple keywords, separate the keywords with commas,

 

and do not use spaces between keywords.

 

You can enter alphanumeric characters and symbols such as #, (, $, !, and

 

&.

 

Do not enter an asterisk (*) or a blank space between the characters or

 

symbols.

 

 

level level

(Optional) Sets the power level of the port.

 

The range is from 0 and 10.

 

To power off the end point, enter 0.

 

To power on the end point

 

If it is a PoE end point, enter 10.

 

If it is not, enter a power level from 1 to 10. The end point

 

determines the appropriate action.

 

 

recurrence

(Optional) Schedules the power-on or power-off event.

importance importance

importance importance—The event occurs if the importance value of

{at minute hour

the end point is less than or equal to the specified importance value. The

day_of_month month

range is from 1 to 100.

day_of_week

at minute hour day_of_month month day_of_week—Specifies the time

time-range

time-range-name}

(24-hour format) in cron format for the recurring event.

 

minute—The range is from 0 to 59. Use * for the wildcard.

 

hour—The range is from 0 to 23. Use * for the wildcard.

 

day_of_month—The range is from 1 to 31. Use * for the wildcard.

 

month—The range is from 1 (January) to 12 (December). Use * for

 

the wildcard.

 

day_of_week—The range is from 0 (Sunday) to 7 (Sunday). Use *

 

for the wildcard.

 

time-rangetime-range-name—Specifies the time range name for the

 

recurring event.

 

The event uses the switch time.

 

 

name name

(Optional) Specifies the EnergyWise-specific port name.

 

You can enter alphanumeric characters and symbols such as #, (, %, !,

 

and &.

 

Do not enter an asterisk (*) or a blank space between the characters or

 

symbols.

 

 

Cisco EnergyWise Configuration Guide

 

OL-19806-03

3-9

 

 

 

Page 53
Image 53
Cisco Systems OL-19806-03 manual Keywords word,word, Recurrence, Importance importance, Time-range