4-32
Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide
OL-18083-01
Chapter 4 Configuring the Cisco PGW 2200 Softswitch Software
Configuring the Execution Environment
Configuring Engine Parameters
For the engine to run correctly, you must modify the following parameters in the Engine section of the
XECfgParm.dat file:
*.IP_Addr1 Enter the IP address of the bge0 interface.
*.IP_Addr2 Enter the IP address of the bge1 interface (if configured).
*.IP_Addr3 Enter the IP address of the bge2 interface (if configured).
*.IP_Addr4 Enter the IP address of the bge3 interface (if configured).
*.Virtual_IP_Addr1 Enter a virtual IP addresses for the
Cisco PGW 2200 Softswitch used for SIP Failover Support
(optional).
*.Virtual_IP_Addr2 Enter a virtual IP addresses for the
Cisco PGW 2200 Softswitch used for SIP Failover Support
(optional).
Parameter Modification
Parameter Modification
engine.CALL_MEM_BLOCK_SIZE Block of memory allocated per call.
Used by MDL.
Set automatically based on the type of
Cisco PGW 2200 Softswitch selected in
engine.SysVirtualSwitch. Any attempt to modify this value
is overwritten.
engine.CALL_MEM_CHUNK_SIZE Memory chunks allocated from the block of memory
designated with engine.CALL_MEM_BLOCK_SIZE.
Set automatically based on the type of
Cisco PGW 2200 Softswitch selected in
engine.SysVirtualSwitch. Any attempt to modify this value
is overwritten.
engine.SendHardwareBlock To enable the Cisco PGW 2200 Softswitch to send
hardware-oriented blocking messages for any blocks that
originate from the media gateways:
true—Sends hardware-oriented blocking messages for
any blocks that originate from the media gateways.
false—Sends only maintenance-oriented blocking
messages for all blocking cases (default).
Note The parameter is automatically added to the
XECfgParm.dat file during the patch installation.