— 29 —
POWER
DATA
STB
T1
DATA DATA DATA
T2
BUSY
ACK
T3
T1: 2.0us MIN
T2: 500ms MIN
T3: 5us TYP
5.3 Description of Input/Output Signals
(1) Input signal
•DATA 1 to DATA 8 . . . 8 bit parallel signal (positive logic)
STB . . . Strobe signal for reading out data (negative logic)
RESET . . . Signal for resetting the entire unit (negative logic 4 ms or more)
(2) Output signal
•ACK . . . 8 bit data signal for requesting data. ACK is issued at the end of the
BUSY signal (negative logic)
BUSY . . . Signal indicating the printer is busy. Input new data when the signal
is in “LOW” condition (positive logic)
PE . . .Signal that shows form cutting (positive logic)
•FAULT. . . . Signal that shows that trouble like mechanism alarm etc. occurred
(3) Other
GND . . . Ground commonly used in the circuit
FRAME GND . . . Frame ground (case ground)
(4) Timing chart
Busy signal timing: Clear timing can be selected by the memory switch.
ACK signal timing: The following kinds of timing can be selected by the memory
switch setting.
Busy signal timing: Clear timing can be selected by the memory switch.
ACK signal timing: The following kinds of timing can be selected by the memory
switch setting.
T4: 5us TYP
T5: 5us TYP