Citizen Systems CBM920II Serial Interface Type, Switch No Baud Rate Parity Factory Setting Bps

Models: CBM920II

1 58
Download 58 pages 51.63 Kb
Page 38
Image 38

7.3 Serial Interface Type

Switch No.

Function

OFF

ON

Factory Setting

1

Character direction

Normal

Inverted

OFF

2 (920)*

CR command

Ignore CR

CR + LF

OFF

2 (3110)

CR command

OFF

3

Reset in

Disable

Enable

ON

4

Memory switch

Disable Setting

Enable Setting

OFF

5

 

 

 

OFF

Transmission rate

 

 

6

The following reference

OFF

and parity

7

 

 

OFF

 

 

 

8

 

 

 

OFF

 

 

 

 

 

 

* Difference may occur in accordance with the emulation set by the memory switch.

Set DIP switch No. 4 to ON. Then turn the printer power on while pressing and holding the FEED switch. The printer enters the manual memory switch setting mode. After manual setting mode, be sure to set this switch to Off.

Baud rate and parity selection

 

Switch No.

 

Baud Rate

Parity

Factory Setting

8

7

6

5

(bps)

 

 

OFF

OFF

OFF

OFF

4800

None

O

OFF

OFF

OFF

ON

1200

None

OFF

OFF

ON

OFF

2400

None

OFF

OFF

ON

ON

4800

None

OFF

ON

OFF

OFF

9600

None

OFF

ON

OFF

ON

19200

None

OFF

ON

ON

OFF

1200

Odd

OFF

ON

ON

ON

2400

Odd

ON

OFF

OFF

OFF

4800

Odd

ON

OFF

OFF

ON

9600

Odd

ON

OFF

ON

OFF

19200

Odd

ON

OFF

ON

ON

1200

Even

ON

ON

OFF

OFF

2400

Even

ON

ON

OFF

ON

4800

Even

ON

ON

ON

OFF

9600

Even

ON

ON

ON

ON

19200

Even

— 35 —