Detailed Parameters
®
38
Section 4 QUANTUM
QUANTUM User Manual
Section 4
Band 1 FC 20.0 Hz to 20.0 kHz
This controls the corner frequency for the low frequency shelving EQ band.
Slope 3 to 12 dB / Octave
Sets the slope of the shelf.
Level -12 to + 12 dB
Amount of boost or cut. Adjustable in 1/2 dB steps.
Band 2,3, 4 FC 20.0 Hz to 20.0 kHz
This controls the center point for the parametric EQ.
Q 0.25 to 16.0
Sets the width of the boost / cut.
Level -12 to + 12 dB
Amount of boost or cut. Adjustable in 1/2 dB steps.
Band 5 FC 20.0 Hz to 20.0 kHz
This controls the corner frequency for the high frequency shelving EQ band.
Slope 3 to 12 dB / Octave
Sets the slope of the shelf.
Level -12 to + 12 dB
Amount of boost or cut. Adjustable in 1/2 dB steps.
There are three crossover points on the QUANTUM, creating 4 bands. Tuning them allows you
to select which frequencies to process with which of the multiband dynamics processors. The
QUANTUM uses phase compensated, Butterworth 1st and 3rd order filters.
Within the crossover menu on the QUANTUM, the following parameters are user adjustable:
Edge 1 Fc 20.0 Hz to 5.0 kHz
Sets the crossover point between bands 1 and 2.
Edge 2 Fc 40.0 Hz to 10.0 kHz
Sets the crossover point between bands 2 and 3.
Edge 3 Fc 79.0 Hz to 20.0 kHz
Sets the crossover point between bands 3 and 4.
Slope 6 or 18 dB / Octave (per band)
Your choice of 2 different slopes for each of the 3 crossover points.
4.8 XOver4.7 EQ (cont.)