Appendix D SYSEX Definitions

QUANTUM

yyThe Setup number, 1-100 (00-63h)

zzByte Count

dd(n)

Program data

The Receive One Setup procedure is used to load a Setup into the QUANTUM. The number of setup bytes to be received

(n)is different for each setup. If the QUANTUM is sent a Receive One setup procedure where the setup number is not a valid RAM destination, it will be ignored.

Request Bulk Dump (49h)

SYS_HEAD, 49(h), F7(h)

When a Request Bulk Dump procedure is received, the QUANTUM will respond with a Receive Bulk Dump proce- dure.

Receive Bulk Dump (48h)

SYS_HEAD 48(h), dd(1st)1 dd(1st)2, ... dd(nth)1, dd(nth)2, F7(h)

dd(n)

Bulk Dump Data

The Receive Bulk Dump procedure is used to load all User Programs into the QUANTUM. A software version num- ber is imbedded in the data.

Receive Key Scan Code (54h)

SYS_HEAD, 54(h), cc, F7(h)

cc Code for the Key Scan (note: there is only one byte, not two)

The Receive Key Scan Code procedure is used to emulate a button press on the front panel of the QUANTUM. See the Key Scan Code Maps for a list of Key Scan codes. The device will respond with a Receive Key Accepted pro- cedure.

*Encoder controls are included, to allow you to emulate encoder moves as well as button presses.

**Config is included to make it accessible through SYSEX commands even though it is not represented by its own button.

Receive Key Accepted (56h)

SYS_HEAD, 56(h), cc1, cc2, F7(h)

cc Code echoed for the Key Scan received. (00(h) if key is invalid)

The Receive Key Accepted procedure is sent from the QUANTUM in response and acceptance of a Receive Scan Code Key or Receive Hold Scan Code Key procedure but is ignored if received by the QUANTUM.

Reset Program (20h)

SYS_HEAD, 20(h), F7(h)

®

72

QUANTUM User Manual

 

 

Page 82
Image 82
dbx Pro QUANTUM user manual Appendix D Sysex Definitions