Appendix C Miscellaneous Clock Info

QUANTUM

C.2 QUANTUM Sync Input (cont.)

not allow the user to change the termination setting. These pieces of equipment are usually provided with a permanent termination. If you use QUANTUM with another piece of terminated equipment in a tapped configuration, you should unterminate QUANTUM’s sync input. The same is true if you wish to use several QUANTUMs in a tapped configuration. QUANTUM can also be used in a daisy chain fashion. In a daisy chain configuration, each piece of equipment can remain terminated (and should if you are using a SuperClock) and so the termination can remain in the default position.

Whatever configuration you choose, always use high-quality 75 ohm coaxial cable for your sync connections. In addi- tion, keep the cable runs as short as possible. The preceding is especially true when using SuperClock because the fre- quencies are much higher. Failure to follow these guidelines could cause decreased audio performance and/or syn- chronization problems.

Daisy Chain Configuration

Sync Source

A

Quantum

C

Tapped Configuration

Sync Source

A

Quantum

C

Fig. C.2

®