Section 6 Application Guide

QUANTUM

6.9 Sample Rate Converter

Hardware

1.Connect AES/EBU or S/PDIF output of the digital source to the QUANTUM’s AES/EBU or S/PDIF input.

2.Connect the QUANTUM’s AES/EBU or S/PDIF output to AES/EBU S/PDIF of DAT machine.

Software

1.Press the UTILITY button to enter the QUANTUM’s utility section. Change the INPUT to AES/EBU or S/PDIF.

2.Change the CLOCK to AES/EBU or S/PDIF.

3.Set SRC to the desired sample frequency.

4.Press the NORM/OUTPUT button twice. This accesses the dither and noise shaping of the output module.

5.Choose which type of dither you would like to use (refer to Section 4.16).

6.Choose which type of noise shaping you would like to use (refer to Section 4.16).

7.Set the Dither Out to All if monitoring dither.

8.Press STORE if you wish to save non-utility changes (refer to Section 3.4)

®

60

QUANTUM User Manual

 

 

Page 70
Image 70
dbx Pro QUANTUM user manual Sample Rate Converter