Table 1-6. System Messages (continued)

Message

Causes

Corrective Actions

 

 

 

The amount of system

Memory has been

If memory has been

memory has changed

added or removed, or a

added or removed, this

 

memory module may

message is informative

 

be faulty.

and can be ignored. If

 

 

memory has not been

 

 

added or removed, check

 

 

the SEL to determine if

 

 

single-bit or multi-bit

 

 

errors were detected and

 

 

replace the faulty

 

 

memory module. See

 

 

"Troubleshooting

 

 

System Memory" on

 

 

page 114.

The file being copied is too large for the destination drive.

The file that you are trying to copy is too large to fit on the disk.

Try increasing disk space on the destination drive by deleting unnecessary files.

Time-of-day not set — please run SETUP program

The time or date stored in the System Setup program does not match the system clock.

Enter the System Setup program and correct the Date and Time options. See "Using the System Setup Program" on page 31. If the problem persists, see "Troubleshooting the System Battery" on page 111.

Timer chip counter 2

A chip on the system

Run the system

failed

board might be

diagnostics. See

 

malfunctioning.

"Running the System

 

 

Diagnostics" on

 

 

page 127.