Dell T105 Systems owner manual Removing the Cooling Fans

Models: T105 Systems

1 190
Download 190 pages 62.21 Kb
Page 84
Image 84

Removing the Cooling Fans

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. Before performing any procedure, see your Product Information Guide for complete information about safety precautions, working inside the computer and protecting against electrostatic discharge.

1Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.

2Open the system. See "Opening the System" on page 47.

3Disconnect the fan’s power cable from the system board.

4If you are removing the smaller hard drive cooling fan (see Figure 3-23):

a Squeeze the two release tabs together at the top of the fan cage that attaches the fan to the chassis bracket mount.

b Lift the fan out.

NOTE: The SAS hard drive cooling fan is present only if a SAS 6i/R integrated controller card is installed.

5If you are removing the larger processor cooling fan:

a Remove the heat sink and shroud assembly. See "Removing the Processor" on page 79. Do not remove the processor, however.

b Press the side release tab that attaches the processor cooling fan to the chassis (see Figure 3-24).

c Press the bottom release tab and shift it forward to maneuver the bottom securing tabs out of their mounting holes (see Figure 3-24).

d Slide the fan toward the back panel and lift the fan out.

84

Installing System Components

Page 84
Image 84
Dell T105 Systems owner manual Removing the Cooling Fans, Slide the fan toward the back panel and lift the fan out