Image 34

8.1

8.2

8.3

8.4

8.5

8.6

8.7

System Reports

Abort

No YES

Restoral: YES

No yes Disarm

Bypass

No YES

schd chg No YES

Code chg No YES

Access Keypads:

System Reports

System Reports

System Reports

Select specific system reports the panel sends to the receiver.

Abort Report

YES allows the panel to send an alarm abort report to the receiver any time an area is disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff Time has not expired. After disarming an area, if any other area remains armed and has zone(s) in alarm, the alarm abort report is not sent.

If the communication type is set to DD, a Warning: Alarm Bell Silenced report is also sent if the alarm bell is silenced.

Note: Abort Reports are not sent for Fire, Fire Verify, or Supervisory type zones.

Restoral Reports

This option allows you to control when and if a zone restoral report is sent to the central station receiver. Press any Select key to display the following options:

NO - Disables the zone restoral report option. Zones continue to operate normally but do not send restoral reports to the receiver.

YES - Enables the zone restoral report option. Zone restorals are sent whenever a zone restores from a trouble or alarm condition.

DISARM - Causes the panel to send restoral reports for a non-24-hour zone whenever a zone that has restored from a trouble or alarm condition is disarmed. All 24-hour zones send restoral reports as they restore.

Bypass Reports

YES allows the panel to send all zone bypasses, resets, and force arm reports to the receiver. The bypass report includes the zone number, zone name, and the user name and number of the individual operating the system. Reports are only sent if O/C User in Communications is set YES for Receiver 1 or Receiver 2.

Schedule Change Reports

YES allows the panel to send all schedule changes to the receiver. The report includes the day, opening time, closing time, extend schedule time, and the user name and number of the individual making the change. Schedule changes made through Remote Link™ are not sent to the printer or Display Events.

Code Change Reports

YES allows the panel to send all code additions, changes, and deletions to the receiver. The code change report includes the user name and number added or deleted and the user name and number of the individual making the change. Code changes made through Remote Link™ are not sent to the printer or Display Events. Reports are only sent if O/C User in Communications is set YES for Receiver 1 or Receiver 2. The default setting is YES.

Access Keypads

Select the keypad addresses (1 through 16) that send door access reports to the receiver. Enter the keypad number using the digit keys. An asterisk next to the number indicates that the keypad is selected. Press COMMAND to display the next set of keypads.

A report is sent with each door access made from the selected keypads. Keypads at addresses not selected still operate the door relay but do not send access reports. The report includes the user number, user name, keypad address, and device name.

XR500 Series Canadian Programming Guide

Digital Monitoring Products

25

Page 34
Image 34
DMP Electronics XR500 manual System Reports

XR500 specifications

DMP Electronics has made significant waves in the tech industry with its innovative XR500 device, a cutting-edge solution that caters to both professional and consumer needs. The XR500 combines advanced technologies with a user-friendly design to deliver an exceptional user experience.

One of the standout features of the XR500 is its powerful processing capabilities. Equipped with a high-performance processor, the device ensures seamless multitasking and quick access to applications. This allows users to handle demanding tasks such as gaming, content creation, and data analysis without experiencing lag or slowdown.

In terms of display, the XR500 boasts a stunning high-resolution screen that enhances visual clarity and color accuracy. Whether you are watching videos, playing immersive games, or editing images, the vibrant colors and sharp details make every experience enjoyable. The device also supports high refresh rates, providing fluid motion essential for fast-paced gaming.

Another critical characteristic of the XR500 is its versatility. It features multiple connectivity options including USB-C, HDMI, and Bluetooth, enabling users to connect a wide range of peripherals and accessories. This flexibility makes the XR500 suitable for various applications, whether you're in a creative professional environment or simply enjoying media at home.

DMP has also focused on the XR500's audio quality. Equipped with advanced sound technologies, the device delivers an immersive audio experience. Clear and rich sound enhances gaming and movie-watching experiences, ensuring that every detail is heard. The integrated speakers are supplemented by options for external sound systems, catering to audiophiles and casual listeners alike.

Battery life is a crucial consideration for any electronic device, and the XR500 does not disappoint. It features a robust battery that supports extended usage times, making it ideal for users who are constantly on the move. Additionally, fast-charging capabilities ensure that the device can be quickly recharged, minimizing downtime.

Lastly, the XR500 is designed with a sleek and modern aesthetic, combining form and function. Its lightweight and portable design make it easy to transport, ideal for professionals who need to work on the go. With an emphasis on user experience, the XR500 is not just a deviceā€”it's a comprehensive solution that meets the diverse needs of modern users. Whether you are a professional seeking performance or a consumer looking for quality, the DMP Electronics XR500 is a compelling choice that stands out in the market.