Digital Monitoring Products XR500 Series Canadian Programming Guide
2
inTroduCTion
1.3 Encrypted Communications (XR500N/XR500E only)
Some installations require secure data communications. DMP offers NIST approved AES encrypted
communication. Use a unique passphrase to enable encrypted communications and provide a secure
meansfordatacommunications.SeeNetworkOptions.
An XR500E panel communicates using AES encryption. If you currently have an XR500N panel installed, you
may purchase a separate feature key to activate encrypted communications using the Feature Upgrade
process. Encrypted communication cannot be enabled on a standard XR500 panel. For more information
on the Feature Upgrade process see Section 21 in this document.
1.4 Programmer Operation
There are 21 programming sections to choose from:
Programming Item Section in This Manual Programming Item Section in This Manual
Initialization 2 Output Information 12
Communication 3 Output Groups 13
Network Options 4 Menu Display 14
Messaging Setup 5 Status List 15
Device Setup 6 Printer Reports 16
Remote Options 7 PC Log Reports 17
System Reports 8 Area Information 18
System Options 9 Zone Information 19
Bell Options 10 Stop 20
Output Options 11 Set Lockout Code 21
Feature Upgrade 22
To choose a section for programming, press any top row Select key when the keypad displays the name of
that section. Sections 2 through 22 contain detailed instructions for each programming step.
1.5 Programmer Lockout Codes
The panel allows you to enter the programming function without entering a lockout code using steps
1to4listedinGettingStarted.Werecommend,however,thatyouinstallaLockoutCodetorestrict
programmingtoonlythosepersonsyourcompanyauthorizes.YoucandothisbyusingtheSETLOCKOUT
CODEfeatureintheProgrammer.TheLockoutCoderestrictsanyunauthorizedpanelprogramming.
Afterresettingthepanelandenteringthecode6653,thekeypaddisplaysPROGRAMMER.PressCOMMAND
toadvancethroughtheprogrammingsectionsuntilSETLOCKOUTCODEdisplays(afterSTOP).Pressany
toprowSelectkey.ThekeypaddisplaysENTERCODE:–.Entera3to5digitProgrammerLockoutCode
andpressCOMMAND.ThekeypaddisplaysENTERAGAINfollowedbyENTERCODE:–.Enterthesame3to
5digitcodeasecondtimeandpressCOMMAND.ThekeypaddisplaysCODECHANGED.
Note:Thepaneldoesnotaccepta5-digitLockoutCodehigherthan65535.
Beforeaccessingprogrammerfunctionsenterthenewcodenumber.WritetheLockoutCodenumberdown
andkeepitinasecureplacewithaccesslimitedtoauthorizedpersonsonly.LostLockoutCodesrequire
thepaneltobesentbacktoDMPforrepair.YoumaycancelaLockoutCodebyentering00000attheSet
LockoutCodecommand.
1.6 Reset Timeout
The panel has a feature that requires you to enter the Programmer within 30 minutes of resetting the
panel.After30minutes,ifyouattempttoprogrambyenteringthe6653(PROG)code,thekeypad
displays:RESETPANEL.Youmustresetthepanelandentertheprogramcodethenbeginprogramming
within the next 30 minutes.
If you are already in the Programmer and do not press any keys on the programming keypad for 30
minutes, the panel terminates programming. All data entered up to that time is Not saved unless you run
the Stop routine.
Note:UsetheStoproutinetoexitpanelProgramming.Ensurethekeypaddisplays“SAVINGPROGRAM”to
save all programming changes entered.