bell Options
Bell Options
10.1
BELL OPTIONS
Bell Options
This section allows you to program the panel bell output functions.
10.2
BELL CUTOFF: 15
Bell Cutoff Time
Enter the maximum time from 1 to 99 minutes the Bell Output remains on. If the area is disarmed, the cutoff time resets. Enter 0 (zero) to provide continuous bell output. The default is 15 minutes.
Note: To support the Alarm Verify feature on an All/Perimeter or Home/Sleep/Away system, set the Bell Cutoff Time to greater than 0.
Note: For SIA
10.3
10.4
Automatic Bell Test
Bell tst No YES Select YES to turn on the Bell Output for 2 seconds each time the system is completely armed from a keypad. This test is delayed until the Closing Wait acknowledge is received (if programmed). If the Closing Wait acknowledge is not received within 90 seconds, the bell test does not occur. Arming performed from an Arming zone or from Remote Link™ does not activate the Bell Test.
|
| Bell Output |
|
| |
Bell outPUT: | 0 | Enter the output number when needed to follow the panel Bell Output operation for |
|
| all action and off conditions. Enter 0 (zero) to disable. |
|
| |
|
| Note: When BELL ACTION is set to T for Temporal Code 3, the Bell Output action for |
|
| an |
10.5
Bell ACTION . . . . .
Bell Action
This section defines the type of Bell Output for zone alarms. Press COMMAND to display the default Bell Output for each zone type. Press any Select key and enter S for a Steady Bell Output, P for a Pulsed output, T for a Temporal Code 3 output, and N for no Bell Output.
Note: Trouble conditions do not activate the Bell Output.
10.5.1
10.5.2
10.5.3
10.5.4
10.5.5
10.5.6
10.5.7
|
|
| Fire Bell Action |
|
|
| |
Fire | Type: | p | Defines Bell Action for Fire Type zones. The default is P. |
|
|
| Burglary Bell Action |
|
|
| |
|
|
| |
Burglary Type: | S | Defines Bell Action for Burglary Type zones and Exit Error output. The default is S. | |
|
|
| Supervisory Bell Action |
|
|
| |
|
|
| |
Suprvsry Type: | N | Defines Bell Action for Supervisory Type zones. The default is N. | |
|
|
| Panic Bell Action |
|
|
| |
|
|
| |
Panic | Type: | N | Defines Bell Action for Panic Type zones. The default is N. |
|
|
| Emergency Bell Action |
|
|
| |
|
|
| |
Emergncy Type: | N | Defines Bell Action for Emergency Type zones. The default is N. | |
|
|
| Auxiliary 1 Bell Action |
|
|
| |
|
|
| |
Auxlry 1 Type: | N | Defines Bell Action for Auxiliary 1 Type zones. The default is N. | |
|
|
| Auxiliary 2 Bell Action |
|
|
| |
|
|
| |
Auxlry 2 Type: | N | Defines Bell Action for Auxiliary 2 Type zones. The default is N. | |
|
|
|
|
Digital Monitoring Products | XR500 Series Canadian Programming Guide |
32