15.5
BURGLARY ZONES:
Burglary Zones
Speciesthekeypadaddresses(1through16)whereallburglaryzonealarmsand
troubles display. Bur glary zones in clude Night, Day, and Exit type zones. Burglary
zone troubles remain in the list until the zone restores. All keypads are selected by
default.
For zone alarms, only the last burglary zone tripped re mains in the list. The alarm
re mains in the list un til another burglary zone goes into alarm, any area of the
system is dis armed, or 10 minutes elapse without an alarm. This ensures that if a
bur glary is in progress the last zone tripped remains in the list even if the zone is
restored.
The keypad buzzer sounds for one second on bur glary alarms.
WhenusingLCDKeypads,thepanelprovidesdistinctspeakertonesfromthekeypad
for Burglary:
On - BurglaryzonealarmandBellOutputorBurglaryBellOutputisON.
Off - Alarm Silence.
YoucanfurtherdenewhichkeypadaddressshowsaBurglaryZoneeventby
entering that area number in the Display Areas menu during Device Setup.
15.6
SPRVISORY ZONES:
Supervisory Zones
Speciesthekeypadaddresses(1through16)whereallsupervisoryzonealarms
and troubles display. Supervisory zones are entered in the sta tus list and sound the
keypad buzzer until a valid user code is entered at any keypad address. If a trouble
condition remains in the display, the buzzer sounds at 10:00 am daily until the
supervisorytroubleisclearedfromtheStatusList.
15.7
PANIC ZONES:
Panic Zones
Speciesthekeypadaddresses(1through16)whereallpaniczonealarmsand
troubles display. The name of the zone remains in the list until the zone re stores.
The keypad buzzer does not sound for panic alarms or troubles.
15.8
EMERGENCY ZONES:
Emergency Zones
Speciesthekeypadaddresses(1through16)whereallemergencyzonealarmsand
troubles display. The name of the zone remains in the list until the zone re stores.
The keypad buzzer does not sound for emer gency alarms or troubles.
15.9
AUX 1 ZONES:
Auxiliary 1 Zones
Speciesthekeypadaddresses(1through16)whereallAuxiliary1zonealarmsand
troubles display. The name of the zone remains in the list until the zone restores.
The keypad buzzer does not sound for Auxiliary 1 alarms or troubles.
YoucanfurtherdenewhichkeypadaddressshowsanAuxiliary1Zoneeventby
entering that area number in the Display Areas menu during Device Setup.
15.10
AUX 2 ZONES:
Auxiliary 2 Zones
Speciesthekeypadaddresses(1through16)whereallAuxiliary2zonealarmsand
troubles display. The name of the zone remains in the list until the zone restores.
The keypad buzzer does not sound for Auxiliary 2 alarms or troubles.
YoucanfurtherdenewhichkeypadaddressshowsanAuxiliary2Zoneeventby
entering that area number in the Display Areas menu during Device Setup.
15.11
COMM PATH TRBL:
ALL NO YES
Communication Trouble
Specieswhencommunicationtroublesaredisplayedonkeypadsthatare
programmedtodisplaySystemMonitorTroubles.DefaultisNO.
Select YES to display communication trouble when any communication path fails.
SelectALLtodisplaycommunicationtroubleonlywhenallpathshavefailed.